Download full-text PDF |
Source |
---|
PLoS One
January 2025
Department of Advanced General Dentistry, College of Dentistry, Yonsei University, Seoul, Korea.
Polylactic acid (PLA) has garnered attention for use in interim dental restorations due to its biocompatibility, biodegradability, low cost, ease of fabrication, and moderate strength. However, its performance under intraoral conditions, particularly under heat and moisture, remains underexplored. This study evaluated the mechanical properties of PLA interim crowns compared with those of polymethylmethacrylate (PMMA) and bisphenol crowns under simulated intraoral conditions with thermocycling.
View Article and Find Full Text PDFInt Ophthalmol
January 2025
Department of Ophthalmology, Peking University Third Hospital, No 49 Huayuan North Road, Haidian District, Beijing, 100191, China.
Purpose: To evaluate clinical outcomes and visual quality 12 months after small incision lenticule extraction (SMILE) for correction of myopia with or without astigmatism in patients during the incipient phase of presbyopia.
Setting: Peking University Third Hospital, Beijing, China.
Design: Retrospective observation study.
Phys Rev Lett
December 2024
MSC, CNRS, Université Paris Cité, UMR 7057, F-75013 Paris, France.
We report on the dynamics of a soliton propagating on the surface of a fluid in a 4-m-long canal with a random or periodic bottom topography. Using a full space-and-time resolved wave field measurement, we evidence, for the first time experimentally, how the soliton is affected by the disorder, in the context of Anderson localization, and how localization depends on nonlinearity. For weak soliton amplitudes, the localization length is found in quantitative agreement with a linear shallow-water theory.
View Article and Find Full Text PDFThis paper introduces an interferometer for single-shot areal quantitative phase imaging at two wavelengths simultaneously, suitable for use with low coherence sources. It operates in reflection geometry with on-axis illumination, so that it can be conveniently applied to surface texture measurements. The system consists of two identical 4f systems forming the reference and sample arm.
View Article and Find Full Text PDFCoherence scanning interferometry (CSI) is a non-destructive method for measuring the microstructure surface topography, but it fails to retrieve the bottom topography because the detection light is blocked by the sidewalls of the high aspect ratio (HAR) samples. Our team has proposed CSI technology with the detection light transparent to the sample to measure the surface topography thus ensuring the numerical aperture of the detection light with high throughput. However, a dedicated optical path to monitor the aberrations caused by the modulation from the sample is necessary and a complex optical path is added for aberration correction, which inevitably increases the design complexity and component costs of the optical system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!