Infections caused by synthetic prostheses are relatively rare (1.5-6%) but serious complication in vascular surgery. There is no doubt that during and immediately after surgery bacterial contamination may occur. An in vitro study was carried out in the Vascutek laboratories, which revealed a high affinity between prostheses in Dacron gel and Rifampicin. This affinity, the result of an ionic bond, was demonstrated by the fact that after 5 days Rifampicin was still present on the prostheses. Encouraged by this result, an experimental study was carried out in sheep. Five sheep were operated on making a prosthetic graft in both of the common carotid arteries: on one side a Gelseal Dacron prosthesis was implanted after being soaked for 15 minutes in a solution containing 1 mg/ml Rifampicin. A Knitted Dacron prosthesis was implanted in the contralateral carotid artery, again after pretreatment with Rifampicin. Explants were made after 2, 24, 48, 72 and 96 hours, and the concentration of Rifampicin on the prostheses was assessed on the basis of the diameter of the inhibition area on Staphylococcus aureus cultures. The results showed that the Gelseal Dacron prostheses maintained Rifampicin concentrations with an antibacterial activity up to 72 hours; this property disappears with the Knitted Dacron prostheses after only 24 hours. These results confirm the high affinity of Gelseal Dacron and Rifampicin also in in vivo experimental models.
Download full-text PDF |
Source |
---|
Interact Cardiovasc Thorac Surg
May 2012
Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan.
There is limited information about the size change of a knitted Dacron graft (Gelseal™) used in the thoracic aorta. We evaluated the diameters of the Gelseal™ grafts at a long-term follow-up for 3.7 ± 1.
View Article and Find Full Text PDFJ Vasc Surg
June 2011
Department of Vascular Surgery and Kidney Transplantation, Heinrich-Heine University, University Hospital, Düsseldorf, Germany.
Objectives: Since 1995, expanded polytetrafluoroethylene (ePTFE) grafts have been implemented in open surgical repair (OSR) of abdominal aortic aneurysms (AAA) and are supposed to show less dilatation than polyester grafts. This study examined differences in graft dilatation and clinical outcome.
Methods: This single-center long-term, prospective randomized study monitored 99 consecutive patients after OSR of AAA.
Eur Heart J
May 2009
Department of Congenital and Structural Cardiology, University Hospital Gasthuisberg, Herestraat 49, B-3000 Leuven, Belgium.
Aims: Whatever the technique used for surgical or endovascular repair of a coarctation of the aorta (CA), long-term complications might occur. Aneurysm formation after patch angioplasty is not uncommon and may lead to a life-threatening condition. Therefore, we were interested in the long-term results of different types of tube grafts, from which a lower degree of dilatation is expected.
View Article and Find Full Text PDFJ Cardiovasc Magn Reson
July 2003
Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK.
We describe a 37-year-old who presented with hemoptysis. Twenty-one years previously he had undergone Dacron patch aortoplasty for coarctation. Initial investigations failed to reveal the cause of the hemoptysis.
View Article and Find Full Text PDFEur J Cardiothorac Surg
March 2001
Department of Radiology, University of Leuven, Gasthuisberg University Hospital, Herestraat 49, B-3000, Leuven, Belgium.
Objectives: Aneurysm formation after patch angioplasty for aortic coarctation is a frequent and potentially lethal complication, necessitating surgical reintervention. Although several mechanisms have been postulated, flow disturbance in a concomitant hypoplastic transverse aortic arch most likely contributes to the aneurysm formation. The outcome of the grafts after redo surgery, however, is unknown.