Download full-text PDF |
Source |
---|
JACC Case Rep
April 2024
Cardiac Surgery, Department of Surgical Sciences, University of Turin, Turin, Italy.
An 84-year-old man presented with dyspnea at rest due to severe mitral regurgitation. He first underwent transventricular mitral valve repair with the Harpoon system, which relapsed owing to rupture of neochords. He was definitively treated with transcatheter mitral valve implantation of the Tendyne system 8 months later.
View Article and Find Full Text PDFArtif Organs
May 2024
Department of Cardiovascular Surgery, Heart Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Background: In conventional left ventricular assist devices (LVAD), a separate outflow graft is sutured to the ascending aorta. Novel device designs may include a transventricular outflow cannula crossing the aortic valve (AV). While transversal ventricular dimensions are well investigated in patients with severe heart failure, little is known about the longitudinal dimensions.
View Article and Find Full Text PDFInnovations (Phila)
August 2023
Cardiothoracic Centre, Freeman Hospital, Newcastle upon Tyne, UK.
Innovations (Phila)
November 2023
Division of Cardiac Surgery, Department of Surgical Sciences, Città della Salute e della Scienza di Torino, University of Turin, Italy.
Objective: Transventricular beating-heart mitral valve repair (TBMVR) with artificial chordae implantation is a technique to treat mitral valve prolapse. Two-dimensional (2D) echocardiography completed with simultaneous biplane view during surgeon finger pushing on the left ventricular (LV) wall (finger test [FT]) is currently used to localize the desired LV access, on the inferior-lateral wall, between the papillary muscles (PMs). We aimed to compare a new three-dimensional (3D) method with conventional FT in terms of safety and better localization of LV access.
View Article and Find Full Text PDFJ Clin Med
February 2023
Division of Cardiac Surgery, Department of Surgical Sciences, Città della Salute e della Scienza di Torino, University of Turin, 10126 Turin, Italy.
The NeoChord procedure is an echo-guided trans-ventricular beating-heart mitral valve repair technique to treat degenerative mitral regurgitation (MR) due to prolapse and/or flail. The aim of this study is to analyze echocardiographic images to find pre-operative parameters to predict procedural success (≤moderate MR) at 3-year follow-up. Seventy-two consecutive patients with severe MR underwent the NeoChord procedure between 2015 and 2021.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!