Prosthetic tracheobronchial stents provide palliative treatment for narrowed airways where surgical resection is inadvisable. Over a 1-year period, 28 Gianturco expanding wire stents were used in 15 patients for nonneoplastic indications: pure fibrous airway stenosis (6), fibroinflammatory stenosis (4), and tracheobronchial malacia (5). Insertion was technically straightforward. A satisfactory airway lumen with immediate improvement in ventilatory function was obtained in all patients. After insertion all patients had an irritation-type cough that either subsided spontaneously (10 patients) or was successfully suppressed with inhaled corticosteroid therapy (5 patients). The most common complication (12 patients) was granuloma formation leading to stent removal in 3 patients with fibroinflammatory stenosis. Other complications were dysphagia (1), suction catheter entrapment (1), and fatal massive hemoptysis (1). At a mean follow-up of 13 months (range, 3 to 19 months) all remaining stents are functioning well with no displacement or infection. Overall results were satisfactory in pure fibrous stenoses and tracheobronchial malacia but poor in the presence of inflammation. Tracheobronchial wire stents can be successfully used in selected patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0003-4975(92)90653-lDOI Listing

Publication Analysis

Top Keywords

wire stents
12
expanding wire
8
patients
8
pure fibrous
8
fibroinflammatory stenosis
8
tracheobronchial malacia
8
stents
5
tracheobronchial
5
stents benign
4
benign tracheobronchial
4

Similar Publications

Laser Welding of Micro-Wire Stent Electrode as a Minimally Invasive Endovascular Neural Interface.

Micromachines (Basel)

December 2024

Laboratory for Neural Interface and Brain Computer Interface, Engineering Research Center of AI & Robotics, Ministry of Education, Shanghai Engineering Research Center of AI & Robotics, MOE Frontiers Center for Brain Science, State Key Laboratory of Medical Neurobiology, Institute of AI & Robotics, Academy for Engineering & Technology, Fudan University, Shanghai 200433, China.

Minimally invasive endovascular stent electrodes are an emerging technology in neural engineering, designed to minimize the damage to neural tissue. However, conventional stent electrodes often rely on resistive welding and are relatively bulky, restricting their use primarily to large animals or thick blood vessels. In this study, the feasibility is explored of fabricating a laser welding stent electrode as small as 300 μm.

View Article and Find Full Text PDF

Patent ductus arteriosus (PDA) stenting is a vital intervention for neonates with ductal-dependent blood flow, offering an attractive alternative to surgical shunt placement. Despite its benefits, the procedure poses risks such as ductal spasm, branch pulmonary artery compromise, and pseudoaneurysm formation. This report presents two complex neonatal cases with distinct outcomes.

View Article and Find Full Text PDF

The use of the snare catheter (SC) technique has been described in the field of interventional cardiology, in particular in the retrieval of a lost device, for example, a dislodged coronary stent, broken coronary wire, and so forth. In the transcatheter aortic valve replacement (TAVR) procedure, some cases have been observed where the anatomy is challenging or there are scenarios where some complications occur during the procedure, which make it necessary to use some tools to achieve the success of the procedure. The SC has shown are very useful either to achieve the ascent of the valve to the annular plane in complex anatomies or as a rescue measure in the event of complications that may arise after valve implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!