Download full-text PDF

Source

Publication Analysis

Top Keywords

[study oximetry
4
oximetry coronary
4
coronary flow
4
flow extracorporeal
4
extracorporeal circulation
4
circulation execution
4
execution pharmacological
4
pharmacological cardiac
4
cardiac arrest]
4
[study
1

Similar Publications

Background: Awake prone positioning (APP) can reportedly reduce the need for intubation and help improve prognosis of patients with acute hypoxemic respiratory failure (AHRF) infected with COVID-19. However, its physiological mechanism remains unclear. In this study, we evaluated the effect of APP on lung ventilation in patients with moderate-to-severe AHRF to better understand the effects on ventilation distribution and to prevent intubation in non-intubated patients.

View Article and Find Full Text PDF

Background: The purpose is to formulate a modified screening protocol for acute respiratory distress syndrome (ARDS) in patients with respiratory support based on saturation of pulse oximetry (SpO) and inspired oxygen concentration (FiO).

Methods: This prospective observational study was conducted from August to October 2020 at the Department of Critical Care Medicine of Yijishan Hospital Affiliated with Wannan Medical College. All patients admitted during the study period and required arterial blood gas analysis and electrocardiogram monitoring were included in this study.

View Article and Find Full Text PDF

Background: COPD ranks as the third leading global cause of mortality. Despite the widespread use of the BODE index and its variants for mortality prediction, their accuracy may be affected by factors like ethnicity, altitude and regional disparities. This study aimed to assess a new altitude-adapted prognostic index in COPD patients at moderate altitudes compared with the BODE and other mortality predictors.

View Article and Find Full Text PDF

Correlation between oxygen reserve index monitoring and blood gas oxygen values during anesthesia in robotic total prostatectomy surgery.

BMC Anesthesiol

January 2025

Department of Anesthesiology and Reanimation, University of Health Sciences, Gulhane Training and Research Hospital, Etlik, Ankara, 06010, Turkey.

Introduction-objective: Hyperoxia is associated with acute lung injury and atelectasis. Arterial blood gas measurement is an invasive method. The Oxygen Reserve Index (ORI) was developed to monitor the oxygen values of patients.

View Article and Find Full Text PDF

Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO measurement in consumer wearables that utilise reflectance pulse oximeters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!