Simple method for the determination of rosiglitazone in human plasma using a commercially available internal standard.

Biomed Chromatogr

Bioanalysis, Drug Metabolism and Pharmacokinetics, Discovery Research, Dr Reddys Laboratories Ltd, Miyapur, Hyderabad 500-050, India.

Published: September 2003

To the best of our knowledge, bioanalytical methods to determine rosiglitazone in human plasma reported in literature use internal standards that are not commercially available. Our purpose was to develop a simple method for the determination of rosiglitazone in plasma employing a commercially available internal standard (IS). After the addition of celecoxib (IS), plasma (0.25 mL) samples were extracted into ethyl acetate. The residue after evaporation of the organic layer was dissolved in 750 microL of mobile phase and 50 microL was injected on to HPLC. The separation was achieved using a Hichrom KR 100, 250 x 4.6 mm C(18) with a mobile phase composition potassium dihydrogen phosphate buffer (0.01 m, pH 6.5):acetonitrile:methanol (40:50:10, v/v/v). The flow-rate of the mobile phase was set at 1 mL/min. The column eluate was monitored by fluorescence detector set at an excitation wavelength of 247 nm and emission wavelength of 367 nm. Linear relationships (r(2) > 0.99) were observed between the peak area ratio rosiglitazone to IS vs rosiglitazone concentrations across the concentration range 5-1000 ng/mL. The intra-run precision (%RSD) and accuracy (%Dev) in the measurement of rosiglitazone were <+/-10.69 and <-12.35%, respectively across the QC levels (50-1000 ng/mL). The extraction efficiency was >80% for both rosiglitazone and IS from human plasma. The lower limit of quantitation of the assay was 5 ng/mL. In summary, the methodology for rosiglitazone measurement in plasma was simple, sensitive and employed a commercially available IS.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.272DOI Listing

Publication Analysis

Top Keywords

mobile phase
12
simple method
8
method determination
8
determination rosiglitazone
8
rosiglitazone human
8
human plasma
8
commercially internal
8
internal standard
8
rosiglitazone
6
plasma
4

Similar Publications

Background: Evidence-based digital therapeutics represent a new treatment modality in mental health, potentially providing cost-efficient, accessible means of augmenting existing treatments for chronic mental illnesses. CT-155/BI 3972080 is a prescription digital therapeutic under development as an adjunct to standard of care treatments for patients 18 years of age and older with experiential negative symptoms (ENS) of schizophrenia. Individual components of CT-155/BI 3972080 are designed based on the underlying principles of face-to-face treatment.

View Article and Find Full Text PDF

Metastatic uveal melanoma (UM) patients often initially present with limited symptoms despite a poor prognosis, complicating communication with patients and caregivers. Early Together (NCT04728113) is a randomized Phase III trial that integrates early palliative care through systematic joint visits involving the palliative care team and the medical oncologist, compared with standard oncological care, in 162 metastatic UM patients beginning systemic treatment. This collaboration aims to enhance patient functioning, improve quality of life and facilitate coping mechanisms.

View Article and Find Full Text PDF

Compound-specific stable isotope analysis (CSIA) using liquid chromatography-isotope ratio mass spectrometry (LC-IRMS) is a powerful tool for determining the isotopic composition of carbon in analytes from complex mixtures. However, LC-IRMS methods are constrained to fully aqueous eluents. Previous efforts to overcome this limitation were unsuccessful, as the use of organic eluents in LC-IRMS was deemed impossible.

View Article and Find Full Text PDF

A simple and efficient validated assay for quantifying 21-deoxycortisol (21-DOC), 17-hydroxyprogesterone (17-OHP), cortisol, and cortisone in human plasma has been developed using ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). Analysis of plasma samples were performed on Atlantis dC18 (3 m) column using a mobile phase of 20.0 mM ammonium acetate and acetonitrile (50:50, : ) that was delivered at isocratic flow rate 0.

View Article and Find Full Text PDF

A non-derivatized high-performance liquid chromatographic (HPLC) method was developed for the simultaneous quantification of hydroxyl acids and their amination products in ammonolysis reaction mixtures. By optimizing the mobile phase composition and pH (0.04 M KHPO-5% methanol, pH = 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!