Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Numerous events may occur during a haemodialysis session, leading to variation in the quantity of dialysis received. The purpose of this study was to identify risk factors for variability in haemodialysis delivery.
Methods: Variability in dialysis delivery was expressed by the coefficient of variation (CV%) and calculated for the volume of blood processed (VBP) for all treatments and the monthly urea reduction ratio (URR) in each patient over an 8 month period. The univariate and multivariate relationships between various predictor variables and the URR and VBP CV% were determined.
Results: Eighty-nine patients were identified who met study criteria. The mean VBP and URR CV% were 10.3 +/- 4.7 and 5.4 +/- 3.8%, respectively. Patients with tunnelled catheters and total nursing-care patients had higher VBP and URR CV%, as evaluated by multivariate analysis. Patients with inadequate dialysis (mean URR <65%) had a higher VBP CV% than those patients with mean URR values > or =65% (14.8 +/- 5.4 vs 9.7 +/- 4.5%; P = 0.01). An accurate determination of the URR in 90% of patients required 14 measurements in patients with catheters vs three and two measurements in arteriovenous fistulae and polytetrafluoroethylene grafts, respectively.
Conclusions: This study demonstrated that the use of a venous tunnelled catheter and dialysis in a total nursing-care unit were the only factors independently associated with greater variability in both VBP and URR. Attention to individual dialysis sessions in patients with tunnelled catheters or in a total nursing-care unit is prudent, particularly when identifying reasons for under-dialysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ndt/gfg297 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!