A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Small-vessel stents for intracranial angioplasty: in vitro comparison of different stent designs and sizes by using CT angiography. | LitMetric

Background And Purpose: Our purpose was to evaluate whether CT angiography is a suitable alternative to conventional angiography in the evaluation of small-vessel stents for intracranial angioplasty.

Methods: CT angiographic appearances of 23 stents of different designs and sizes (2.0, 3.0, and 4.0 mm) were investigated after they were filled with a solution of 0.9% NaCl or diluted contrast medium. For each stent, artificial lumen narrowing (ALN) was measured, and the difference in the number of pixels with a Hounsfield value below 200 HU between the two filling states, DIFF(HU<200), was calculated to provide an objective indicator of the size of the evaluable stent diameter.

Results: With a window width of 1500 HU at a window level of 400 HU, ALN ranged from 66.8% to 97.7% in the group of 2.0-mm stents and from 38.6% to 66.8% in the groups of 3.0- and 4.0-mm stents. For the 2.0-mm stents, DIFF(HU<200) was zero. In the groups of 3.0- and 4.0-mm stents, DIFF(HU<200) ranged from 0.3 to 6.7, corresponding to a diameter of 0.13-3.0 mm, when the pixel size was presupposed to be 0.449 mm.

Conclusion: CT angiographic evaluation of small-vessel patency after stent placement is considerably impaired by ALN. Stent manufacturers should be aware of potential artifacts caused by their stents during noninvasive diagnostic studies such as CT angiography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7973988PMC

Publication Analysis

Top Keywords

small-vessel stents
8
stents intracranial
8
designs sizes
8
intracranial angioplasty
4
angioplasty vitro
4
vitro comparison
4
comparison stent
4
stent designs
4
sizes angiography
4
angiography background
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!