A recombinant transposase, TniA, a basic DNA binding protein, was chromatographically purified and characterized by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) methods. Escherichia coli cells, overexpressing native TniA, were ultrasonically disrupted and the clarified supernatant was used as starting material for anion-exchange chromatography on SOURCE1 15Q 4.6/100 PE (Tricorn), at pH 7.5. This initial step was proven to be a fast and simple way of removing acidic proteins like proteases. TniA was collected from the flow-through fraction and applied onto HiTrap heparin HP 5 ml in order to capture the basic TniA. This was followed by cation-exchange chromatography through Mono S 5/50 GL (Tricorn), at pH 6.5 which resulted in a purity of TniA of about 95%. The molecular mass of TniA was determined to 62 869 rel. mol. mass units with MALDI-TOF-MS and the identity of the protein was confirmed by peptide mass fingerprinting of trypsin-digested TniA. Partial amino acid sequencing was achieved after derivatization of tryptic peptides using Ettan CAF MALDI Sequencing Kit and post source decay. The fact that transposases are DNA-binding and that many of them possess basic isoelectric point values suggest that the outlined purification protocol may serve as a general method for the purification of recombinant nontagged transposases and other basic DNA-binding proteins.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0021-9673(03)00922-1 | DOI Listing |
J Am Soc Mass Spectrom
January 2025
Maastricht MultiModal Molecular Imaging Institute (M4i), Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.
Drug toxicity during the development of candidate pharmaceuticals is the leading cause of discontinuation in preclinical drug discovery and development. Traditionally, the cause of the toxicity is often determined by histological examination, clinical pathology, and the detection of drugs and/or metabolites by liquid chromatography-mass spectrometry (LC-MS). While these techniques individually provide information on the pathological effects of the drug and the detection of metabolites, they cannot provide specific molecular spatial information without additional experiments.
View Article and Find Full Text PDFDiagn Microbiol Infect Dis
January 2025
Henan Provincial Chest Hospital tuberculosis within Six/Critical Illness Area, Henan Infectious Diseases(TB)Clinical Research Center, Zhengzhou, Henan, 450001, PR China. Electronic address:
Purpose: This study aims to evaluate the clinical diagnostic value of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for tuberculosis and drug-resistant tuberculosis.
Patients And Methods: Totally 201 pulmonary tuberculosis patients were recruited retrospectively. All patients underwent smear microscopy, Mycobacterium growth indicator tube (MGIT) 960 culture, loop-mediated isothermal amplification (LAMP) molecular testing, Xpert MTB/RIF (Xpert), and MassARRAY assay which is a MALDI-TOF MS based method.
J Mass Spectrom
February 2025
Center for Bioinformatics and Computational Biology, University of Delaware, Newark, Delaware, USA.
The development of a real-time system for characterizing individual biomolecule-containing aerosol particles presents a transformative opportunity to monitor respiratory conditions, including infections and lung diseases. Existing molecular assay technologies, although effective, rely on costly reagents, are relatively slow, and face challenges in multiplexing, limiting their use for real-time applications. To overcome these challenges, we developed digitalMALDI, a laser-based mass spectrometry system designed for single-particle characterization.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy.
The identification and typing of bacteria are very expensive and time-consuming due to their growth times, and the expertise needed. MALDI-TOF MS represents a fast technique, reproducible with molecular approaches. This technique is still poorly applied in Legionella surveillance with estimation occurring only at the genus level.
View Article and Find Full Text PDFParasit Vectors
January 2025
Shoklo Malaria Research Unit, Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Mae Ramat, Thailand.
Background: Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is proposed for mosquito species identification. The absence of public repositories sharing mass spectra and open-source data analysis pipelines for fingerprint matching to mosquito species limits the widespread use of this technology. The objective of this study was to develop a free open-source data analysis pipeline for Anopheles species identification with MALDI-TOF MS.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!