A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Peritoneal function tests: usefulness of simplified methods. | LitMetric

The Peritoneal Equilibration Test (PET) as standardized by Twardowski (T) and simplified Mass Transfer Coefficients (MTC) as per Garred (G) and Krediet (K) have been employed in our patients to assess: 1) the reproducibility of results, 2) correlation between methods, and 3) usefulness of patient categorization by simplified methods in contrast to PET patterns. We have performed 29 standardized PET (Dianeal 2.5%) in 24 stable CAPD patients. We have collected dialysate samples at 0, 30, 60, 120, 180 and 240 minutes. With this data we were able to calculate the dialysate/plasma ratio for PET, MTC as per Garred and MTC as per Krediet. Our results were not significantly different from data reported by the original authors, except for PET D/P urea at 240': 0.91 +/- 0.07(T) vs. 0.87 +/- 0.08 (our), p < 0.05. In our patients, good correlation was found between PET and MTC for urea, creatinine, and glucose, using both formulae (G and K). Patient categorization as High, High Average, Low Average, and Low by MTCs can well predict PET categorization with acceptable sensitivity and good specificity. We conclude there is good reproducibility of the methods. There is also a close correlation between PET, K and G methods for solute transport evaluation and patient categorization. Simplified methods can be substituted for the more complex ones.

Download full-text PDF

Source

Publication Analysis

Top Keywords

simplified methods
12
patient categorization
12
pet
8
mtc garred
8
categorization simplified
8
pet mtc
8
correlation pet
8
average low
8
methods
6
peritoneal function
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!