Antibodies to synaptophysin interfere with transmitter secretion at neuromuscular synapses.

Neuron

Department of Biological Sciences, Columbia University, New York, New York 10027.

Published: October 1992

The involvement of synaptophysin, a synaptic vesicle-specific protein, in transmitter release at neuromuscular synapses was studied by intracellular application of synaptophysin antibodies into presynaptic neurons. Polyclonal antibodies or their Fab fragments were loaded into spinal neurons by injection into one of the early blastomeres of Xenopus embryos 1 day prior to culturing or, alternatively, directly through a whole-cell recording pipette at the soma of cultured neurons. At synapses made by antibody-loaded neurons in culture, the spontaneous synaptic currents showed marked reduction in frequency without significant change in their mean amplitude. The impulse-evoked synaptic currents showed reduced amplitude and increased failure rate. These results suggest that interference with synaptophysin function by antibody binding inhibits transmitter secretion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0896-6273(92)90038-fDOI Listing

Publication Analysis

Top Keywords

transmitter secretion
8
neuromuscular synapses
8
synaptic currents
8
antibodies synaptophysin
4
synaptophysin interfere
4
interfere transmitter
4
secretion neuromuscular
4
synapses involvement
4
involvement synaptophysin
4
synaptophysin synaptic
4

Similar Publications

Norepinephrine in vertebrates and its invertebrate analog, octopamine, regulate the activity of neural circuits. We find that, when hungry, larvae switch activity in type II octopaminergic motor neurons (MNs) to high-frequency bursts, which coincide with locomotion-driving bursts in type I glutamatergic MNs that converge on the same muscles. Optical quantal analysis across hundreds of synapses simultaneously reveals that octopamine potentiates glutamate release by tonic type Ib MNs, but not phasic type Is MNs, and occurs via the G-coupled octopamine receptor (OAMB).

View Article and Find Full Text PDF

Wireless power-up and readout from a label-free biosensor.

Biomed Microdevices

January 2025

Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA.

Wearable and implantable biosensors have rapidly entered the fields of health and biomedicine to diagnose diseases and physiological monitoring. The use of wired medical devices causes surgical complications, which can occur when wires break, become infected, generate electrical noise, and are incompatible with implantable applications. In contrast, wireless power transfer is ideal for biosensing applications since it does not necessitate direct connections between measurement tools and sensing systems, enabling remote use of the biosensors.

View Article and Find Full Text PDF

Feasibility, Acceptability, and Validity of Home Continuous Glucose Monitoring-Based Oral Glucose Tolerance Test in Youth.

J Clin Endocrinol Metab

December 2024

Center for Pediatric Research in Obesity and Metabolism and Division of Pediatric Endocrinology, Diabetes, and Metabolism, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania.

Context: Home-based approaches to type 2 diabetes (T2D) screening in youth may facilitate early diagnosis.

Objective: To evaluate feasibility, acceptability, and validity of a continuous glucose monitoring (CGM)-based oral glucose tolerance test (OGTT).

Design: Prospective observational study.

View Article and Find Full Text PDF

: The vagus nerve, which connects the brain and gastrointestinal tract, helps to maintain immune balance in the intestines. Gut-specific integrins, on the other hand, help to keep immune cells in the intestines. Since immune cells from outside the intestines can significantly affect the outcome of strokes, we investigated how immune cells from the intestines affect the immune response in the brain during intracerebral hemorrhage (ICH).

View Article and Find Full Text PDF

Ultrafast self-healing zwitterionic hydrogels reinforced by carboxymethyl chitosan-oxidized hyaluronic acid and graphene oxide toward high-performance strain sensors.

Int J Biol Macromol

January 2025

Jiangsu Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, College of Chemical Engineering, Nanjing Forestry University, Nanjing 210037, China; Jiangsu Provincial Key Lab for the Chemistry and Utilization of Agro-Forest Biomass, Nanjing 210037, China. Electronic address:

Inspired by the inherent recuperative ability of organisms in nature, researchers have dedicated significant efforts towards developing self-healing hydrogel sensors. Although the works on self-healing hydrogels have made great progress, achieving hydrogel sensors combining with rapid and efficient healing capability, excellent mechanical properties and high sensing sensitivity remains a challenging task. In this study, we proposed a novel approach for fabricating a self-healing conductive zwitterionic hydrogel sensor by adding carboxymethyl chitosan (CMCs) and oxidized hyaluronic acid (OHA) to induce dynamic Schiff base reaction, and graphene oxide (GO) nanosheets as physical crosslinker.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!