A new, simple, and accurate ultrasonic method is elaborated for thyroid volume determination with commercially available high-resolution real-time equipment. The method takes into account the special and variable shape of the thyroid. The measurements were taken in three perpendicular sections. Volume calculations were done by applying the corrected ellipsoid model and computer-aided numerical integration, as well as by the conventional simple ellipsoid model. The accuracy of the method was tested by comparing direct measurements of a silicone rubber phantom with ultrasonography of a tissue-equivalent thyroid phantom. Both phantoms were modeled as casts of the same thyroid, which was obtained at autopsy. From the phantom measurements the deviation between the volume calculated by numerical integration or the corrected ellipsoid method and the real volume determined directly with the silicone rubber phantom was less than 5% on average, while volume calculations using the conventional ellipsoid model involved about +20% systematic error. In vivo studies in 40 subjects gave similar results: the ratios of the volumes calculated by simple and corrected ellipsoid method and by numerical integration [V(E), V(CE), and V(NI), respectively] were [V(E)/V(CE)] = 1.19 +/- 0.11 and [V(NI)/V(CE)] = 1.02 +/- 0.11. In conclusion corrected ellipsoid method is suggested for the clinical practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jcu.1870200505 | DOI Listing |
Can J Ophthalmol
January 2025
Department of Ophthalmology and Vision Sciences, the Hospital for Sick Children, University of Toronto, Toronto, ON, Canada; Program in Genetics & Genome Biology, SickKids Research Institute, Toronto, ON, Canada. Electronic address:
Objective: Assess safety and effectiveness of subretinal gene replacement therapy at 18 months post treatment.
Design: Retrospective, longitudinal study conducted at the Hospital for Sick Children in Toronto, Canada.
Participants: Patients with bi-allelic RPE65 variants, early onset retinal degeneration, and residual viable retina who underwent voretigene neparvovec r-zyl gene replacement therapy.
Eye (Lond)
January 2025
Save Sight Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia.
Purpose: To determine how Hardy-Rand-Rittler (HRR) colour vision testing correlates with visual functional and structural assessments in Cone and Cone-Rod Dystrophy.
Methods: Thirty-four Cone and 69 Cone-Rod Dystrophy patients diagnosed by electroretinography (ERG) at the Save Sight Institute in Sydney were included in a retrospective analysis. Each patient's HRR colour vision test scores were compared with markers of cone and rod system function including visual acuity (VA), ERG responses, changes on Spectral Domain Optical Coherence Tomography (OCT) and Fundus Autofluorescence.
Ophthalmol Sci
November 2024
Faculty of Medicine, Dentistry and Health Sciences, Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Australia.
Purpose: Emerging clinical trials for inherited retinal disease (IRD) require an understanding of long-term progression. This longitudinal study investigated the genetic diagnosis and change in retinal structure and function over 10 years in rod-cone dystrophies (RCDs).
Design: Longitudinal observational follow-up study.
Am J Ophthalmol Case Rep
March 2025
Department of Ophthalmology, Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, USA.
Purpose: To describe a rare case of presumed bilateral acute idiopathic maculopathy (AIM) in a pediatric patient.
Observation: An 11-year-old male was evaluated for a "fuzzy Dorito-shaped" spot in the central vision of his right eye (OD) that started 3 days before presenting to our clinic. On examination, best-corrected visual acuity (BCVA) was counting fingers at 5 feet OD, and 20/25 in the left eye (OS).
Taiwan J Ophthalmol
November 2024
Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan.
Purpose: This study aimed to investigate optical coherence tomography (OCT) characteristics in hydroxychloroquine (HCQ) retinopathy and their correlation with visual acuity among Taiwanese patients.
Materials And Methods: We retrospectively recruited patients undergoing long-term HCQ treatment who had received examinations of best-corrected visual acuity and OCT scans. We observed disruptions in the ellipsoid zone (EZ) and retinal pigment epithelium (RPE) across different retinal regions.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!