The validity of various electrocardiographic P wave measurements was tested in 48 patients by comparing them to left atrial dimensions determined by echocardiography (echo), a proved method of left atrial size estimation. Of all the measurements considered, only the width of the P wave (PW), the P terminal force in lead V1 (PV1), and the PW/PR segment ratio (PW/PR) showed statistically significant correlations with left atrial size measurements by echo, with r values of 0-746, 0-491, and 0-479, respectively. The results indicated that P widths in excess of 105 ms were present in all the patients who had left atria equal to or greater than 3-8 cm by echo and in 11 per cent of patients without atrial enlargement (false positives), and that when measurements were less than 105 ms left atrial enlargement was unlikely.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC482954 | PMC |
http://dx.doi.org/10.1136/hrt.37.12.1281 | DOI Listing |
Herzschrittmacherther Elektrophysiol
January 2025
Klinik für Elektrophysiologie/Rhythmologie, Ruhr-Universität Bochum, Bochum, Deutschland.
Atrial fibrillation (AF) ablation is associated with a lower likelihood of death and surgical heart failure (HF) interventions in patients with HF. This effect is mainly driven by reduced all cause and cardiovascular death following ablation. Ablation also results in improved left ventricular (LV) function, decreased AF burden and AF regression.
View Article and Find Full Text PDFRadiol Cardiothorac Imaging
February 2025
From the Department of Cardiology (L.P., W.J., J.L., W.Q., Y.X., Y.K., Q.Z., Y.C.), Department of Geriatrics (K.W.), and Center of Rare Diseases (Y.C.), West China Hospital, Sichuan University, No. 37, Guo Xue Road, Chengdu, Sichuan 610041, China; and Wexner Medical Center, College of Medicine, The Ohio State University, Columbus, Ohio (Y.H.).
Purpose To assess the predictive value of left atrial (LA) fast long-axis strain derived from cardiac MRI for thrombotic events (TEs) in individuals with hypertrophic cardiomyopathy (HCM). Materials and Methods This secondary analysis of an ongoing prospective trial (Chinese Clinical Trial Registry: ChiCTR1900024094) included consecutive participants with HCM without atrial fibrillation (AF) who underwent cardiac MRI from January 2012 to December 2020. The LA fast long-axis strain was obtained by semiautomatically tracking the distance between the atrioventricular junction and the midposterior LA wall.
View Article and Find Full Text PDFCirc Heart Fail
January 2025
Cardiology Division, Massachusetts General Hospital, Harvard Medical School, Boston (Y.L., J.L.J., G.D.L.).
Background: Objective indices of functional capacity in patients with diabetic cardiomyopathy and stage B heart failure (HF) have not been comprehensively defined. We sought to characterize the cardiopulmonary exercise characteristics of individuals with diabetic cardiomyopathy at high risk for overt HF.
Methods: The relationships from cardiopulmonary exercise testing with clinical and laboratory characteristics of participants with diabetic cardiomyopathy were evaluated using baseline data from the ARISE-HF trial (Aldose Reductase Inhibition for Stabilization of Exercise Capacity in Heart Failure).
Front Cardiovasc Med
January 2025
Department of Cardiology, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China.
Background: Dextrocardia is a rare congenital condition, affecting approximately 1 in 10,000-12,000 individuals. When combined with atrial fibrillation (AF), it becomes even rarer. "One-stop" surgery, including combined radiofrequency ablation (RFA) and left atrial appendage occlusion (LAAO), has become a common clinical treatment for patients with AF who develop cerebral infarction despite regular oral anticoagulants.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiology, Changhai Hospital, Shanghai 200433, China.
Background: Several studies have demonstrated a notable increase in the incidence of atrial arrhythmias among individuals with atrial septal defect (ASD) occluder. Although the sequential dilation technique has been proposed as the mainstream technique for transseptal puncture with ASD occluder, it is associated with substantial risks and technical difficulties.
Case Summary: We report a patient who underwent catheter ablation for atrial fibrillation and had a large ASD occluder.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!