Background: Dilatation of the ascending aorta concomitant with aortic valve disease is occasionally associated with progressive enlargement of the ascending aorta or acute aortic dissection (AAD). However, surgical procedure of choice for the aorta and its indication are controversial.

Patients And Methods: From July 1995 to August 2001, 10 patients with a moderately dilated ascending aorta (mean diameter, 52+/-4.8 mm) underwent concurrent aortic valve replacement (AVR) and aortoplasty. The aortic valve was bicuspid in eight patients. To tailor the ascending aorta 30-35 mm in diameter, the aortic wall was partially resected along the aortotomy, and the aorta was directly closed.

Results: Operation time and most of other perioperative variables were comparable to those of patients who underwent isolated AVR. The aortic diameter was reduced to 36.1+/-4.1 mm. Nine patients survived to hospital discharge uneventfully, but one patient developed disruption of the suture line in the aorta and died. During follow-up, no patient suffered AAD but redilatation was observed in one patient. In the two problematic patients, the ascending aorta was larger than 55 mm, and its media was histologically abnormal.

Conclusion: In patients with dilated ascending aorta less than 55 mm in diameter, aortoplasty can be a procedure of choice. However, a prosthetic graft replacement is recommended when the diameter of the ascending aorta is larger than 55 mm.

Download full-text PDF

Source

Publication Analysis

Top Keywords

ascending aorta
32
aortic valve
16
dilated ascending
12
aorta
11
ascending
8
valve disease
8
procedure choice
8
aorta diameter
8
aorta larger
8
aortic
7

Similar Publications

Robust preclinical models of asymmetric ventricular loading in late gestation reflecting conditions such as hypoplastic left heart syndrome are lacking. We characterized the morphometry and microvascular function of the hypoplastic left ventricle (LV) and remaining right ventricle (RV) in a sham-controlled late gestation fetal lamb model of impaired left ventricular inflow (ILVI). Singleton fetuses were instrumented at ∼120 days gestational age (dGA; term is ∼147 days) with vascular catheters, an aortic flow probe and a deflated left atrial balloon.

View Article and Find Full Text PDF

Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].

View Article and Find Full Text PDF

Background: Individuals harbouring pathogenic variants are at risk for aneurysms/dissections throughout the arterial tree. Based on prior reports of sex differences in thoracic aortic aneurysm/dissection, we investigated the sexual dimorphism for vascular events in variant-harbouring patients.

Methods: We analysed two large pedigrees comprising 84 individuals segregating pathogenic missense variants affecting the same p.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!