Angiography with 180 degrees arc was performed using a rapidly rotating stereoradiographic device and a single injection of contrast medium. Duration of rotation of the X-ray tube through 180 degrees was 2.25 sec. The angiograms displayed in a rotating manner were three-dimensional with depth information. Every adjacent angiograms were obtained by the rapidly rotating X-ray tube at slightly different angles and positions, resulting in paired stereo images. The angiograms can be displayed on side-by-side monitors and viewed stereoscopically with a stereoviewer. Rotating images were displayed at 30 frames/sec (60 fields/sec) and were viewed in a fluorographic manner. To apply the data to angiocardiography the following procedures were required: 1) the start of rotation of the X-ray tube was synchronized with the R wave of the EKG, 2) suspension of respiration, and 3) the subject's upper extremities were immobilized at his head. To obtain left atrial angiograms the following steps were taken: 1) the circulation time from the pulmonary artery to the left atrium was estimated by injecting 15 ml contrast medium into the pulmonary artery under the fixed X-ray tube, then, 2) X-ray exposures of 20 fields/sec were obtained during 15 sec, and 3) left atrial arteriograms were taken by using the rotating X-ray tube referring to the circulation time. With this method, stenotic lesions of the coronary arteries and collateral pathways were easily observed simultaneously with morphological changes in a 180 degrees arc.(ABSTRACT TRUNCATED AT 250 WORDS)
Download full-text PDF |
Source |
---|
J Comput Assist Tomogr
January 2025
Department of Radiology, College of Medicine, University of Florida, Gainesville, FL.
Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.
Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.
Hemorrhagic pleural effusion as the sole manifestation of pancreatitis is exceedingly rare and often presents diagnostic challenges due to its misleading symptoms. We report the case of an adult male with a large left-sided black pleural effusion secondary to chronic necrotizing pancreatitis. The patient presented with progressive shortness of breath and cough, with a history of alcohol use and a previous diagnosis of acute severe pancreatitis.
View Article and Find Full Text PDFPak J Med Sci
January 2025
Ruichao Miao Department of Reproductive Center, Qingdao Women and Children's Hospital, Qingdao, Shandong Province 266000, P.R. China.
Objective: To assess and compare efficacy of 4-dimensional hysterosalpingo-contrast sonography (4D-HyCoSy) and X-ray hysterosalpingography (HSG) for fallopian tube examination.
Methods: Clinical data of patients with suspected tubal infertility, who underwent examinations in Qingdao Women and Children's Hospital from September 2021 to December 2023, were retrospectively analyzed. Of them, 40 patients received laparoscopy and dye test+ 4D-HyCoSy (4D-HyCoSy group), and 36 patients received laparoscopy and dye test +HSG (HSG group).
Cureus
December 2024
Gastroenterology and Hepatology, Monmouth Medical Center, Long Branch, USA.
Lemmel syndrome involves a periampullary duodenal diverticulum (PAD), a pouch-like outpouching near the ampulla of Vater, compressing the common bile duct. We describe a case of severe abdominal pain in a patient who had a large periampullary diverticulum, managed with surgical intervention after an initial failed endoscopic retrograde cholangiopancreatography (ERCP). An elderly female patient in her early 90s arrived at the emergency department with severe cramping pain localized to the right upper quadrant of her abdomen, progressively intensifying over several weeks.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
January 2025
U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.
Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).
Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!