The results of a double blind study to evaluate the efficiency of prophylactic endovenous indomethacin versus placebo for prevention of intraventricular hemorrhage (IVH) in newborn infants between 28 to 36 weeks of age who were intubated at the delivery room and required mechanical ventilation in NICU are presented. Fourty six patients required mechanical ventilation, but 14 neonates had IVH evaluated by ultrasound when were admitted to the Unit. At least 32 infants were studied, 16 for each group. There were no differences between the groups in weight, gestational age, sex and delivery way. The mobility was the same in relation to hialine membrane disease, sepsis, pneumonie and pneumotorax. The placebo group had more frequency of PDA and mortality (P < 0.5). There were no differences in mean airway pressure and arterial gases, also in glucose, platelets and urinary volume. The indomethacin group had mayor urinary density and FeNa but the results were always in normal ranges. The IVH was the same in both groups. We concluded that the indomethacin at the levels used did not produced alterations, and if the IVH is not prevented, were observed lesser severity of the same and the frequency of PDA and mortality are lesser. But still is necessary more number of cases for best conclusions.

Download full-text PDF

Source

Publication Analysis

Top Keywords

required mechanical
8
mechanical ventilation
8
frequency pda
8
pda mortality
8
[indomethacin prevention
4
prevention subependymal-intraventricular
4
subependymal-intraventricular hemorrhage
4
hemorrhage preterm
4
preterm newborns
4
newborns conventional
4

Similar Publications

Impact of under-assisted ventilation on diaphragm function and structure in a porcine model.

Anesthesiology

January 2025

Department of Anesthesiology and Critical Care Medicine B (DAR B), Saint-Eloi Hospital, University Teaching Hospital of Montpellier, 80 avenue Augustin Fliche, 34295 Montpellier, France.

Background: Long-term controlled mechanical ventilation (CMV) in intensive care unit (ICU) induces ventilatory-induced-diaphragm-dysfunction (VIDD). The transition from CMV to assisted mechanical ventilation is a challenge that requires clinicians to balance over-assistance and under-assistance. While the effects of over-assistance on the diaphragm are well known, we aimed to assess the impact of under-assistance on diaphragm function and structure in piglet model with pre-existing VIDD (after long-term CMV) or without VIDD (short-term CMV).

View Article and Find Full Text PDF

Complex biological systems undergo sudden transitions in their state, which are often preceded by a critical slowing down of dynamics. This results in longer recovery times as systems approach transitions, quantified as an increase in measures such as the autocorrelation and variance. In this study, we analysed paediatric patients in intensive care for whom mechanical ventilation was discontinued through removal of the endotracheal tube (extubation).

View Article and Find Full Text PDF

Automating alloy design and discovery with physics-aware multimodal multiagent AI.

Proc Natl Acad Sci U S A

January 2025

Laboratory for Atomistic and Molecular Mechanics, Massachusetts Institute of Technology, Cambridge, MA 02139.

The design of new alloys is a multiscale problem that requires a holistic approach that involves retrieving relevant knowledge, applying advanced computational methods, conducting experimental validations, and analyzing the results, a process that is typically slow and reserved for human experts. Machine learning can help accelerate this process, for instance, through the use of deep surrogate models that connect structural and chemical features to material properties, or vice versa. However, existing data-driven models often target specific material objectives, offering limited flexibility to integrate out-of-domain knowledge and cannot adapt to new, unforeseen challenges.

View Article and Find Full Text PDF

Metalgel Fiber with Excellent Electrical and Mechanical Properties.

ACS Appl Mater Interfaces

January 2025

National Laboratory of Solid State Microstructures, College of Engineering and Applied Sciences, Nanjing University, Nanjing 210023, China.

With the rapid advancement of soft electronics, particularly the rise of fiber electronics and smart textiles, there is an urgent need to develop high-performance fiber materials with both excellent electrical and mechanical properties. However, existing fiber materials including metal fibers, carbon-based fibers, intrinsically conductive polymer fibers, and composite fibers struggle to simultaneously meet the requirements. Here, we introduce a metalgel fiber with a unique structure.

View Article and Find Full Text PDF

Background/aims: Preformed zirconia crowns have emerged as the preferred choice for restoring damaged primary incisors. However, they differ from natural teeth in their biophysical properties and can potentially alter the overall response of crowned teeth to a traumatic load. This in silico study aimed to compare the response of three different traumatic loading conditions for the (i) natural (M1) and (ii) zirconia-restored tooth models (M2) models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!