The tension-time index (TTI) has been used to estimate mechanical load, energy utilization, blood flow, and susceptibility to fatigue in contracting muscle. The TTI can be defined, for a rhythmically contracting muscle, as the product of average force development divided by maximum tetanic force times duty cycle [contraction time / (contraction + relaxation time)]. In this study, the TTI concept was applied to isolated diaphragm via a method that allowed TTI to be clamped at a predetermined value. The hypothesis tested was that, at constant TTI, muscle energetics and the extent of fatigue would vary with stimulation frequency. Isolated diaphragm strips were stimulated at 25, 50, 75, or 100 Hz for 4 min, one per second. Duty cycle was continuously adjusted to maintain TTI at 0.07, which was near the highest TTI tolerated for 4 min, at 20-Hz stimulation. At the end of the fatigue run, muscles were either immediately frozen for determination ATP, creatine, and creatine phosphate concentrations (n = 6) or stimulated for evaluation of low- and high-frequency fatigue (n = 5). Results demonstrated no difference in the extent of fatigue or in the final ATP and creatine phosphate concentrations between groups. Large within-run increases in duty cycle were required at low stimulation frequencies, but only small increases were required at the highest frequencies. The results demonstrate that, at a constant TTI, similar fatigue properties predominate at all stimulation frequencies with no clear distinction between high- and low-frequency fatigue. The method of clamping TTI during fatigue may be useful for evaluating energetics and contractile function between treatment groups in isolated muscle when treatment influences baseline contractile characteristics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/japplphysiol.00237.2003 | DOI Listing |
For indirect time-of-flight (iToF) cameras, we proposed a modeling approach focused on addressing random error. Our model characterizes random error comprehensively by detailing the propagation of error introduced by signal light, ambient light, and dark noise through phase calculation and system correction processes. This framework leverages correlations between incident light and tap responses to quantify noise impacts accurately.
View Article and Find Full Text PDFSci Rep
January 2025
School of ECE, Adama Science and Technology University, Adama, Ethiopia.
This paper details the hardware implementation of a Universal Converter controlled by an Artificial Neural Network (ANN), utilizing key components such as six Insulated Gate Bipolar Transistors (IGBTs), two inductors, and two capacitors for energy storage and voltage smoothing. A Digital Signal Processor (DSP) serves as the core controller, processing real-time input and feedback signals, including voltage and current measurements, to dynamically manage five operational modes: rectifier buck, inverter boost, DC-DC buck, DC-DC boost, and AC voltage control. The pre-trained ANN algorithm generates pulse-width modulation (PWM) signals to control the switching of the IGBTs, optimizing timing and duty cycles for efficient operation.
View Article and Find Full Text PDFJ Phys Chem A
January 2025
Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, United States.
We present direct frequency comb cavity ring-down spectroscopy with Vernier filtering as a straightforward approach to sensitive and multiplexed trace gas detection. The high finesse cavity acts both to extend the interaction length with the sample and as a spectral filter, alleviating the need for dispersive elements or an interferometer. In this demonstration, a free running interband cascade laser was used to generate a comb centered at 3.
View Article and Find Full Text PDFMetabolites
January 2025
Department of Animal and Dairy Science, University of Georgia, Athens, GA 30602, USA.
When measuring real-time in vivo muscle fatigue with electromyography (), data collection can be compromised by premature sensor removal or environmental noise; therefore, the objective of this study was to develop a postmortem in vivo methodology to induce muscle fatigue and measure it using EMG. Barrows ( = 20) were stratified by weight and randomly allocated into one of two treatments. The treatments consisted of barrows being subjected to a hog electric stunner super-contraction cycle () or not () postmortem.
View Article and Find Full Text PDFvariants cause a range of epilepsy syndromes, including Dravet syndrome, leading to early cognitive and functional impairment. Despite advances in medical management, drug-resistant epilepsy remains common. Vagal nerve stimulation (VNS) has been suggested reducing seizure frequency in these patients but there is a lack of long-term follow-up, quantitative analysis that corrected for confounding factors such as antiseizure medications (ASMs) and the impact of VNS settings on response.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!