Syringe filtration methods for examining dissolved and colloidal trace element distributions in remote field locations.

Environ Sci Technol

Department of Marine Science, University of Southern Mississippi, Stennis Space Center, Mississippi 39529, USA.

Published: September 2003

It is well-established that sampling and sample processing can easily introduce contamination into dissolved trace element samples if precautions are not taken. However, work in remote locations sometimes precludes bringing bulky clean lab equipment into the field and likewise may make timely transport of samples to the lab for processing impossible. Straightforward syringe filtration methods are described here for collecting small quantities (15 mL) of 0.45- and 0.02-microm filtered river water in an uncontaminated manner. These filtration methods take advantage of recent advances in analytical capabilities that require only small amounts of waterfor analysis of a suite of dissolved trace elements. Filter clogging and solute rejection artifacts appear to be minimal, although some adsorption of metals and organics does affect the first approximately 10 mL of water passing through the filters. Overall the methods are clean, easy to use, and provide reproducible representations of the dissolved and colloidal fractions of trace elements in river waters. Furthermore, sample processing materials can be prepared well in advance in a clean lab and transported cleanly and compactly to the field. Application of these methods is illustrated with data from remote locations in the Rocky Mountains and along the Yukon River. Evidence from field flow fractionation suggests that the 0.02-microm filters may provide a practical cutoff to distinguish metals associated with small inorganic and organic complexes from those associated with silicate and oxide colloids.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es0341182DOI Listing

Publication Analysis

Top Keywords

filtration methods
12
syringe filtration
8
dissolved colloidal
8
trace element
8
sample processing
8
dissolved trace
8
remote locations
8
clean lab
8
trace elements
8
methods
5

Similar Publications

Background: Whether there is a causal relationship between childhood obesity and increased risk of chronic kidney disease (CKD) remains controversial. This study sought to explore how body size in childhood and adulthood independently affects CKD risk in later life using a Mendelian randomization (MR) approach.

Methods: Univariate and multivariate MR was used to estimate total and independent effects of body size exposures.

View Article and Find Full Text PDF

Albumin-seeking NIR dyes for high-sensitive imaging of glomerular filtration barrier breakdown.

Biomaterials

January 2025

Joint Laboratory of Opto-Functional Theranostics in Medicine and Chemistry, The First Hospital of Jilin University, Changchun, 130021, PR China; State Key Laboratory of Supramolecular Structure and Materials, Center for Supramolecular Chemical Biology, College of Chemistry, Jilin University, Changchun, 130012, PR China. Electronic address:

The kidney, vital for metabolic balance, faces risks of severe diseases if dysfunctional. The glomerular filtration barrier (GFB), crucial for blood filtration, disrupts in conditions like diabetic nephropathy or nephritides, resulting in proteinuria or even renal failure. Monitoring GFB integrity is essential for early diagnosis or prognostic monitoring.

View Article and Find Full Text PDF

Due to the global outbreaks caused by pathogens, disinfection has attracted widespread attention, especially as the final inactivation step in wastewater treatment plants (WWTPs). Ultraviolet (UV) radiation is regarded as one of low carbon disinfection methods without chemical agents, but in practice, the effects are sometimes unsatisfactory, e.g.

View Article and Find Full Text PDF

Classroom air quality in a randomized crossover trial with portable HEPA air cleaners.

J Expo Sci Environ Epidemiol

January 2025

Department of Environmental and Occupational Health, Joe C. Wen School of Population & Public Health, University of California, Irvine, CA, USA.

Background: Children living in communities with lower socioeconomic status and higher minority populations are often disproportionately exposed to particulate matter (PM) compared to children living in other communities.

Objective: We assessed whether adding HEPA filter air cleaners to classrooms with existing HVAC systems reduces indoor air pollution exposure.

Methods: From July 2022 to June 2023, using a block randomized crossover trial of 17 Los Angeles Unified School District elementary schools, classroom PM concentrations were monitored and compared for 99 classrooms with HEPA filter air cleaners and 87 classrooms with non-HEPA filter air cleaners.

View Article and Find Full Text PDF

Can parenchymal volume analysis replace nuclear renal scans for split renal function before and after partial nephrectomy with warm ischemia?

Urol Oncol

January 2025

Department of Urology, Sun Yat-sen University Cancer Center, Guangzhou, P. R. China; State Key Laboratory of Oncology in Southern China; Collaborative Innovation Center for Cancer Medicine, Guangzhou, China; State Key Laboratory of Oncology in Southern China, Guangzhou, P. R. China. Electronic address:

Article Synopsis
  • The study evaluates parenchymal volume analysis (PVA) as a potential alternative to nuclear renal scan (NRS) for assessing split renal function (SRF) before and after partial nephrectomy (PN) with warm ischemia.
  • Preoperatively, PVA showed a strong correlation with NRS findings, indicating its reliability for SRF assessment (49.4% vs. 50.0%, P = .501).
  • Results suggest that while PVA is consistent with NRS preoperatively, the efficacy of PVA remains uncertain for post-operative SRF evaluation after PN, indicating a need for further investigation.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!