A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of antiendothelial cell antibodies by an enzyme-linked immunosorbent assay using antigens from cell lysate: minimal interference with antinuclear antibodies and rheumatoid factors. | LitMetric

The objective of the present work was to set up a routine test adapted to screening for antiendothelial cell antibodies (AECAs) in serum samples with minimal interference from antinuclear antibodies (ANAs) or rheumatoid factors (RFs). We compared the titers of AECAs titrated following two enzyme-linked immunosorbent assays (ELISAs): (i) an ELISA with ethanol-fixed EA.hy926 monolayers as the antigenic substrate and (ii) an ELISA with nucleus-depleted lysates prepared from EA.hy926 cells and normalized for protein (1.0 to 1.7 mg/ml) and DNA (< or =0.1 microg/ml) contents as a surrogate substrate (postnuclear supernatant ELISA [PNS-ELISA]). The AECA titers in 51 serum samples, including 28 samples containing ANAs, were compared. A significantly positive correlation (r = 0.77; P < 0.001) between the two series was shown only for the ANA-negative serum samples. Conversely, ANAs or RFs in samples were shown not to interfere in tests for AECAs by the PNS-ELISA. AECAs recognize their antigenic targets in postnuclear supernatants, which is representative of the endothelial antigenic content, with improvement of the reliability of the assay, a prerequisite to application of the assay for their evaluation in clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC193897PMC
http://dx.doi.org/10.1128/cdli.10.5.934-939.2003DOI Listing

Publication Analysis

Top Keywords

serum samples
12
antiendothelial cell
8
cell antibodies
8
enzyme-linked immunosorbent
8
minimal interference
8
interference antinuclear
8
antinuclear antibodies
8
rheumatoid factors
8
samples
5
detection antiendothelial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!