Rationale And Objectives: In myocardial contrast echocardiography (MCE), power Doppler imaging is more sensitive to contrast agent (microbubble) than gray-scale B-mode imaging; however, no data exist regarding the optimal contrast dose in power Doppler imaging. This study examined the optimal dose of contrast agent for power Doppler in assessing coronary stenosis.

Methods: Three grades of coronary stenosis were produced in 6 open-chest dogs. MCE was performed with gray-scale and power Doppler during continuous infusion of 0.2 mL/min FS-069. Thereafter, MCE was repeated with power Doppler during continuous infusion of 0.1 mL/min FS-069.

Results: Although the videointensity in the stenosed bed with power Doppler (214 +/- 14) was greater than gray scale (35 +/- 17) during 0.2 mL/min FS-069 infusion (P < 0.0001), power Doppler failed to identify milder coronary stenoses because videointensity in stenosed bed was quickly saturated with contrast agent. The videointensity in the stenosed bed with power Doppler (127 +/- 49) during 0.1 mL/min FS-069 infusion was greater than gray scale (35 +/- 17) during 0.2 mL/min FS-069 infusion (P < 0.0001), and all levels of stenosis were identified with power Doppler, even though the dose of contrast agent was half of that of gray scale imaging. The correlation between videointensity and myocardial blood flow was better in the case of power Doppler at 0.1 mL/min FS-069 infusion (r = 0.77, P < 0.0001) than in the case of gray scale imaging at 0.2 mL/min FS-069 infusion (r = 0.66, P < 0.01).

Conclusions: These data support the need for a lower dose of contrast agent for power Doppler than for gray scale to detect milder coronary stenosis and avoid saturation of imaging fields.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.RLI.0000073641.93901.b9DOI Listing

Publication Analysis

Top Keywords

power doppler
48
contrast agent
24
ml/min fs-069
24
gray scale
20
fs-069 infusion
20
dose contrast
16
power
12
doppler
12
doppler imaging
12
coronary stenosis
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!