A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anatomical and computed tomographic analysis of C1 vertebra. | LitMetric

Anatomical and computed tomographic analysis of C1 vertebra.

Clin Neurol Neurosurg

Department of Neurosurgery, School of Medicine, Dokuz Eylül University Hospital, Dokuz Eylül University, Inciralti 35340, Izmir, Turkey.

Published: September 2003

Craniovertebral junction surgery requires knowledge regarding the anatomy of this region, particularly the C1 vertebra. Both C1 laminectomy and C1-2 instrumentation necessitate preoperative information about bony landmarks and the vertebral artery. This study compares the results obtained from anatomic and computed tomographic measurements of C1 bony landmarks. 31 C1 cervical vertebrae were measured; the C1 AP diameter, and C1 transverse diameter, the facet diameter, the distance between the anterior tubercle and the anterior aspect of the C1 lateral mass on a lateral view, the distance between the midline and the vertebral artery groove on the outer cortex of the posterior arch of C1 anatomically and computed tomographically. Anatomic measurements were performed by an anatomist using a Vernier caliper accurate to 0.1 mm, whereas the computed tomographic measurements were performed by a radiologist on bone window computed tomography (CT). The mean values and the differences between two measurement modalities were analysed using a paired t-test. There was no statistical difference between the results obtained by anatomical and radiological measurements for six parameters. There was, however, a statistically significant difference between two modalities regarding the distance between the midline and vertebral artery groove on the outer cortex of posterior arch of C1, while slightly different, the difference is within 1 mm and, therefore, not clinically significant. It is concluded that CT reflects most anatomical details of bony landmarks of C1.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0303-8467(03)00037-4DOI Listing

Publication Analysis

Top Keywords

computed tomographic
12
bony landmarks
12
vertebral artery
12
tomographic measurements
8
distance midline
8
midline vertebral
8
artery groove
8
groove outer
8
outer cortex
8
cortex posterior
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!