Purpose: To describe a practical method of aiding nasotracheal intubation in a cleft palate patient with previous pharyngoplasty using a suction catheter under tactile guidance. Problems of airway management in these patients are also discussed.

Clinical Features: A 26-yr-old woman presented for elective Le Fort maxillary osteotomy. She had a history of cleft lip and palate and subsequent palatoplasty and pharyngeal flap. She had no symptoms of upper airway obstruction or obstructive sleep apnea. Preoperative examination revealed a hypernasal voice and patent nasal passages. Anesthesia was induced and the patient paralyzed. An attempt to pass a 6.5-mm cuffed endotracheal tube through the right nostril met with resistance. A suction catheter was introduced into the nostril, while a finger was positioned over the flap and the velopharyngeal port, until its tip rested against the flap, the catheter coiled and a small loop could be palpated past the patent velopharyngeal port. The catheter was then hooked into the oropharynx. The endotracheal tube was "railroaded" over it and advanced into the glottis. There was minimal bleeding and no desaturation during the procedure.

Conclusion: Preoperative determination of the type of pharyngoplasty is essential to understand the anatomy of the patent velopharyngeal port. A history of pharyngeal flap infection, hyponasal voice or upper airway obstruction suggests possible port stenosis. We describe a tactile guided technique that is useful and practical. Use of a flexible suction catheter of small external diameter minimizes the potential for trauma, bleeding and creation of false passages.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF03018717DOI Listing

Publication Analysis

Top Keywords

suction catheter
12
velopharyngeal port
12
airway management
8
cleft palate
8
pharyngeal flap
8
upper airway
8
airway obstruction
8
endotracheal tube
8
patent velopharyngeal
8
catheter
5

Similar Publications

Purpose: To evaluate the effectiveness and safety of an upgraded integrated vacuum suction catheter in semi-rigid ureteroscopic laser lithotripsy (VC-URSL) compared to traditional methods for treating impacted upper ureteral stones.

Patients And Methods: This prospective, randomized controlled trial was conducted from September 2022 to March 2024 at a single center, enrolling 95 patients aged 18 to 70 years with a single radiopaque impacted upper ureteral stone. Participants were randomized into two groups: the VC-URSL group used an integrated vacuum suction catheter featuring a stainless steel stabilizing tube and a narrowed distal end to prevent obstruction, while the T-URSL group underwent standard ureteroscopic lithotripsy without vacuum assistance.

View Article and Find Full Text PDF

We report the first multicenter, prospective, randomized noninferiority controlled trial of steerable ureteroscopic renal evacuation (SURE) for nephrolithiasis treatment. Candidates for laser lithotripsy ≥18 years with ≥1 renal stone ≥7 mm and 7-20 mm stone burden were randomized 1:1 SURE ureteroscopy (URS). SURE was performed using the CVAC Aspiration System, a novel steerable irrigation-aspiration catheter.

View Article and Find Full Text PDF

Objective: To describe indications for and demonstrate the technique to perform a transtracheal aspirate in horses. Transtracheal aspirate is indicated to collect samples for cytology and bacteriologic culture in cases of suspected pneumonia or other lower respiratory tract disease.

Animals: 1 healthy university-owned horse was used for demonstration purposes.

View Article and Find Full Text PDF

Advancements in aspiration catheter tip design for thrombectomy: a comprehensive patent review.

Front Med Technol

November 2024

Department of BioMechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Delft, Netherlands.

Thrombus removal from the human body is facilitated through the utilization of aspiration catheters during minimally invasive thrombectomy procedures, where a pressure differential guides the targeted tissue through a flexible tubular medical instrument. In this paper, we present a patent analysis of thrombectomy aspiration catheter tip designs sourced from the EspaceNet database. Our findings reveal that enhancing the operability of aspiration catheters can be achieved by improving ease of positioning or suction capacity, whether through active or passive means.

View Article and Find Full Text PDF

Transseptal Sheath Perfused with High Concentration Heparinized Saline for Reducing Sheath-associated Thrombus.

Pacing Clin Electrophysiol

December 2024

Department of Cardiology, Shanghai General Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China.

Article Synopsis
  • The study focused on the use of transseptal sheaths (TSS) for atrial fibrillation (AF) ablation, aiming to prevent thromboembolism through a simple saline flush management technique.
  • In the retrospective study involving over 4,700 AF patients, complications were low, with no acute strokes, and only a few thromboembolic issues occurring post-procedure.
  • The prospective study showed no thrombus formation in 127 procedures using high concentration heparinized saline, demonstrating that this method is both safe and effective for preventing thrombus during AF radiofrequency ablation.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!