Background: The natural history of aneurysms ends in rupture and death. In 1990 the first endovascular exclusion of an aneurysm, using an endoluminal graft implanted through the femoral arteries was performed. More recently, the same procedure has been used for aneurysms of the thoracic aorta.
Aim: To report our experience with endovascular treatment of thoracic aorta aneurysms.
Material And Methods: Analysis of 14 patients (nine male), aged 30 to 79 years, treated between May 2001 and August 2002.
Results: The mean diameter of the aneurysms was 6.9 cm. The etiology was atherosclerotic in nine patients. The Excluder device (Gore) was preferentially used. There was no operative mortality or paraplegia. One patient had a transient leg monoparesis that reverted completely. No patient had type I endoleaks. Two patients had type II endoleaks on discharge, that sealed spontaneously. In a follow up, ranging from 2 to 17 months, one patient died of a bronchopneumonia and no aneurysm rupture has been detected.
Conclusions: The short term results of endoluminal treatment of thoracic aorta aneurysms are excellent. This treatment is less invasive and has less complications than conventional surgery.
Download full-text PDF |
Source |
---|
Acad Radiol
January 2025
Medical Image Processing Group, 602 Goddard building, 3710 Hamilton Walk, Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104 (M.L., M.A., J.K.U., Y.T., C.W., N.P., S.M., D.A.T.). Electronic address:
Rationale And Objectives: Cardiovascular toxicity is a well-known complication of thoracic radiation therapy (RT), leading to increased morbidity and mortality, but existing techniques to predict cardiovascular toxicity have limitations. Predictive biomarkers of cardiovascular toxicity may help to maximize patient outcomes.
Methods: The machine learning optimal biomarker (OBM) method was employed to predict development of cardiotoxicity (based on serial echocardiographic measurements of left ventricular ejection fraction and longitudinal strain) from computed tomography (CT) images in patients with thoracic malignancy undergoing RT.
Radiol Case Rep
March 2025
Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, State University of New York (SUNY), Downstate Health Sciences University, Brooklyn, NY, USA.
Extensive congenital pulmonary airway malformation (CPAM) of the left fetal lung and associated marked dextroposition of the fetal heart were noted at 21 weeks' gestation. The right fetal lung appeared compressed with the cardiomediastinal shift angle measuring approximately 20 degrees. Potential subsequent right pulmonary hypoplasia was considered.
View Article and Find Full Text PDFEur Heart J Imaging Methods Pract
January 2025
Cardiology Department, Hospital Universitario Quirónsalud Madrid, Calle Diego de Velázquez, 1, Madrid 28223, Spain.
Aims: To assess the reproducibility of 4D-Flow cardiac magnetic resonance (CMR) parameters in the descending thoracic aorta-DTAo-(regurgitant fraction [RF], end-diastolic reverse flow [EDRF], and holodiastolic flow reversal [HDR]), and the relationship with RF in the sinotubular junction (STJ), and the left ventricular end-diastolic volume index (LVEDVI) in patients with chronic aortic regurgitation (AR).
Methods And Results: A descriptive study of these variables was conducted. A receiver operating characteristic curve was used to determine the optimal cut-off point.
BMC Cardiovasc Disord
January 2025
Department of Thoracic and Cardiovascular Surgery, Nanjing First Hospital, Nanjing Medical University, Nanjing, China.
Background: The aim of this study was to investigate whether the hybrid technique yields superior outcomes in comparison with the total arch replacement combined with frozen elephant trunk (TAR + FET) for acute aortic dissection (AAD) involving the aortic arch.
Methods: This retrospective cohort study using propensity-score matching included patients with AAD involving the aortic arch admitted to Nanjing First Hospital and Shanghai General Hospital from January 2015 to June 2020. The in-hospital and mid-term outcomes were compared between patients who received hybrid treatment (n = 136) and those who received TAR + FET (n = 415).
Sci Rep
January 2025
University of Ulsan, 93 Daehak-ro, Nam-gu, Ulsan, 680-749, Republic of Korea.
This study employed large eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) model to investigate transitional flow characteristics in an idealized model of a healthy thoracic aorta. The OpenFOAM solver pimpleFoam was used to simulate blood flow as an incompressible Newtonian fluid, with the aortic walls treated as rigid boundaries. Simulations were conducted for 30 cardiac cycles and ensemble averaging was employed to ensure statistically reliable results.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!