Purpose: The hemodynamic changes induced by infrarenal aortic crossclamping have been well documented, but the effects of such crossclamping on cerebral perfusion are unknown. To investigate these effects, we used near-infrared spectroscopy (NIRS) to monitor regional cerebral oxygen saturation (rSO2) during infrarenal aortic crossclamping in a piglet model.

Methods: The study involved 19 piglets, each weighing 7.8 +/- 1 kg. The NIRS sensor was placed on each animal's forehead. General anesthesia was induced, and the infrarenal abdominal aorta was mobilized through a laparotomy. After heparin (1 mg/kg) was administered, crossclamps were applied proximally and distally. A 2 mm segment was resected from the proximal aortic stump, and an aorto-aortic anastomosis was performed.

Results: Crossclamping lasted for 30.6 +/- 6.7 min. Between the time of baseline measurement and clamp application, the rSO2 did not decrease significantly (65.4%+/- 8.9% vs. 62.4%+/- 7.8%). However, significant decreases in the rSO2 occurred between baseline measurement and clamp removal (65.4%+/- 8.9% vs. 55.7%+/- 8.9%; P<0.01), between baseline measurement and the end of surgery (65.4%+/- 8.9% vs. 57.7%+/- 7.5%; P<0.01), and between clamp application and removal (62.4%+/- 7.8% vs. 55.7%+/- 8.9%; P<0.01). At these same intervals, no intergroup differences occurred in the temperature, heart rate, or mean arterial pressure.

Conclusion: Infrarenal aortic crossclamping significantly decreases the rSO2. NIRS, which has the advantages of being non-invasive and continuous, may be useful for monitoring this variable intraoperatively.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1525-1594.2003.07195.xDOI Listing

Publication Analysis

Top Keywords

infrarenal aortic
12
aortic crossclamping
12
near-infrared spectroscopy
8
monitor regional
8
regional cerebral
8
cerebral oxygen
8
oxygen saturation
8
induced infrarenal
8
baseline measurement
8
measurement clamp
8

Similar Publications

Endoanchors for the distal fixation of iliac limb in endovascular aneurysm repair.

J Vasc Surg Cases Innov Tech

April 2025

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.

View Article and Find Full Text PDF

Transaortic endarterectomy (TE) is an effective and durable method of restoring patency in the aorta afflicted with atherosclerotic disease, which most commonly affects the infrarenal aorta and common iliac artery. When the suprarenal aorta is involved, the disease is usually confined to the orifices of the visceral vessels without obstruction of the aortic lumen. In rare cases, dense, calcified, exophytic, and amorphous lesions causing severe luminal obstruction, termed coral reef atherosclerosis (CRA) of the suprarenal aorta, may occur.

View Article and Find Full Text PDF

Mycotic aneurysms are rare but severe complications that can arise from systemic bacterial infections, including those caused by Salmonella species. These aneurysms can progress rapidly and are associated with high mortality. A 62-year-old man with poorly controlled type 2 diabetes mellitus presented to the hospital in septic shock.

View Article and Find Full Text PDF

Clarifying the inceptive pathophysiology of hypertensive heart disease helps to impede the disease progression. Through coarctation of the infrarenal abdominal aorta (AA), we induced hypertension in minipigs and evaluated physiological reactions and morpho-functional changes of the heart. Moderate aortic coarctation was achieved with approximately 30 mmHg systolic pressure gradient in minipigs.

View Article and Find Full Text PDF

The Effect of Aneurysm Diameter on Perioperative Outcomes Following Complex Endovascular Repair.

J Vasc Surg

January 2025

Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA. Electronic address:

Objectives: Endovascular aneurysm repair (EVAR) for large infrarenal abdominal aortic aneurysms (AAA) has been associated with worse outcomes compared to EVAR for smaller AAAs. Whether these findings apply to complex AAAs (cAAA) remains uncertain.

Methods: We identified all intact complex EVAR (cEVAR) from 2012-2024 in the Vascular Quality Initiative.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!