Background: Motexafin lutetium (MLu; Antrin) is a photosensitizer that is taken up by atherosclerotic plaque and concentrated within macrophages and vascular smooth muscle cells. After photoactivation with far red light, MLu facilitates production of cytotoxic oxygen radicals that mediate apoptosis. We assessed the safety and tolerability of phototherapy (PT) with MLu in patients undergoing percutaneous coronary intervention with stent deployment.

Methods And Results: An open-label, phase I, drug and light dose-escalation clinical trial of MLu PT enrolled 80 patients undergoing de novo coronary stent deployment. MLu was administered to 79 patients by intravenous infusion 18 to 24 hours before procedure, and photoactivation was performed after balloon predilatation and before stent deployment. Clinical evaluation, serial quantitative angiography, and intravascular ultrasound were performed periprocedurally and at 6 months follow-up. MLu PT was well tolerated without serious dose-limiting toxicities, and side effects (paresthesia and rash) were minor. No adverse angiographic outcomes were attributed to phototherapy.

Conclusions: This study demonstrates that coronary MLu PT seems safe, and the maximum well-tolerated MLu dose and range of tolerated light doses were identified. These data can be used in phase II efficacy trials of MLu PT for the treatment of coronary atherosclerosis or vulnerable plaque.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.CIR.0000087602.91755.19DOI Listing

Publication Analysis

Top Keywords

stent deployment
12
mlu
9
phase drug
8
drug light
8
light dose-escalation
8
motexafin lutetium
8
red light
8
undergoing percutaneous
8
percutaneous coronary
8
coronary intervention
8

Similar Publications

Artificial Intelligence-Guided Inverse Design of Deployable Thermo-Metamaterial Implants.

ACS Appl Mater Interfaces

January 2025

Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.

Current limitations in implant design often lead to trade-offs between minimally invasive surgery and achieving the desired post-implantation functionality. Here, we present an artificial intelligence inverse design paradigm for creating deployable implants as planar and tubular thermal mechanical metamaterials (thermo-metamaterials). These thermo-metamaterial implants exhibit tunable mechanical properties and volume change in response to temperature changes, enabling minimally invasive and personalized surgery.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.

View Article and Find Full Text PDF

Background: Protruding coronary artery stents can adversely affect transcatheter aortic valve replacement (TAVR) procedure. Current evidence on the topic is limited.

Aims: We aim to study the clinical feasibility and safety of flaring of protruding coronary artery stents before TAVR to reduce interaction with transcatheter heart valves.

View Article and Find Full Text PDF

The management of gastrointestinal anastomotic leaks post surgery is a considerable challenge, characterized by elevated morbidity and mortality, particularly in cases of esophageal-jejunal anastomotic leaks. Diverse endoscopic intervention techniques have been utilized with enhanced success. We present a case where a 57-year-old patient with Siewert type II esophageal cardia cancer underwent endoscopic deployment of a fully covered stent into a fistula resulting from anastomotic leakage, following a laparoscopic proximal gastrectomy with Roux-en-Y and double tract reconstruction.

View Article and Find Full Text PDF

Purpose: This study aims to investigate the indications and therapeutic efficacy of flow-diverting stents (FDSs) in the management of extracranial carotid artery aneurysms (ECAAs) and dissections.

Methods: A retrospective analysis was conducted on 18 patients treated for ECAAs with an FDS between 2010 and 2024. Patient demographics, aneurysm characteristics, procedural details, and clinical and radiologic follow-up outcomes were extracted from medical records.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!