Developing priority criteria for hip and knee replacement: results from the Western Canada Waiting List Project.

Can J Surg

Western Canada Waiting List Project Hip and Knee Replacement Panel, Edmonton, Alta.

Published: August 2003

Introduction: The Western Canada Waiting List Project (WCWL), a federally funded partnership of 19 organizations, was created to develop tools for managing waiting lists. The WCWL panel on hip and knee replacement surgery was 1 of 5 panels constituted under this project.

Methods: The panel developed and tested a collection of standardized clinical criteria for setting priorities among patients awaiting hip and knee replacement. The criteria were applied to 405 patients in 4 provinces. Regression analysis was used to determine the set of criteria weights that collectively best predicted clinicians' overall urgency ratings. Inter-rater and test-retest reliability was assessed from 6 videotaped patient interviews, scored by orthopedic surgeons, related professionals and general practitioners.

Results: The priority criteria accounted for over two-thirds of the observed variance in overall urgency ratings (adjusted R2 = 0.676). The panel modified the criteria and weights based on the empirical findings and on clinical judgement. The reliability of the priority criteria for the hip and knee replacement tool was among the strongest of the 5 instruments developed in the WCWL project.

Conclusions: The panel considered the criteria easy to use and reasonably reflective of expert surgical judgement regarding clinical urgency for hip and knee replacement. Further development and testing of the tool appears warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3211637PMC

Publication Analysis

Top Keywords

hip knee
20
knee replacement
20
priority criteria
12
criteria
8
criteria hip
8
western canada
8
canada waiting
8
waiting list
8
list project
8
criteria weights
8

Similar Publications

Background: Osteoarthritis (OA) often leads to pain and functional limitations, impacting work and daily life. Physical activity (PA) is an important part of the treatment. Wearable activity trackers (WATs) offer a novel approach to promote PA but could also aid in finding a sustainable PA level over time.

View Article and Find Full Text PDF

Analyzing video footage of falls in older adults has emerged as an alternative to traditional lab studies. However, this approach is limited by the labor-intensive process of manually labeling body parts. To address this limitation, we aimed to validate the use of the AI-based pose estimation algorithm (OpenPose) in assessing the hip impact velocity and acceleration of video-captured falls.

View Article and Find Full Text PDF

Enhancing gait mechanics: The effectiveness of a novel walking aid.

J Orthop Sci

January 2025

Department of Orthopaedic Surgery, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-8509, Japan.

Background: A walking support orthosis known as the e-foot®, a rubber orthotic worn from the hip to the forefoot to enhance joint flexibility and movement, has been developed to assist elderly people and individuals with walking impairments. Despite its widespread acceptance and positive reception in some care settings, the precise impact of this device on gait dynamics remains unexplored. This study aims to bridge this gap by comparing the walking speeds of healthy volunteers using the e-foot® against their normal walking speeds.

View Article and Find Full Text PDF

Patients with knee osteoarthritis (KOA) often have impaired muscle function of the weight-bearing muscles, particularly in the knee and hip joints. This can lead to a significant loss of strength and power and may play a role in the perceived instability of the knee joint. The purpose of this study was to compare the maximum isometric strength of the hip abductor and knee extensor muscles between patients with KOA with and without perceived instability.

View Article and Find Full Text PDF

Background: Carbon fiber custom dynamic orthoses have been used to improve gait mechanics after lower limb trauma in military service members, with the goal of restoring function and improving outcomes. However, the effects of commercially available carbon fiber orthoses available to civilians on lower extremity joint kinetics and kinematics are poorly understood.

Research Question: The aim of this study was to examine the effect of two commercially available orthoses on lower extremity kinematics and kinetics in individuals with lower limb trauma.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!