Objective: Late failure after successful third ventriculostomy is rare, and death caused by failure of a previously successful third ventriculostomy has been reported on four occasions. We describe a simple innovation that adds little morbidity and has the potential to reduce the advent of death after late failure of endoscopic third ventriculostomy.

Methods: After endoscopic fenestration of the floor of the third ventricle, a ventricular catheter and subcutaneous reservoir are placed via the endoscope path. With acute blockage and neurological deterioration, cerebrospinal fluid can be removed via needle puncture of the reservoir until consultation with a neurosurgeon.

Results: From 1979 to 2003, more than 240 endoscopic third ventriculostomies have been performed at our institution, with one death after late failure. The revised technique was devised after this death and has been performed on 21 patients to date.

Conclusion: The addition of a reservoir adds little time and morbidity to the procedure and offers the potential to sample cerebrospinal fluid, measure intracranial pressure, and reduce mortality associated with late failure of endoscopic third ventriculostomy.

Download full-text PDF

Source
http://dx.doi.org/10.1227/01.neu.0000073534.04767.b1DOI Listing

Publication Analysis

Top Keywords

late failure
20
endoscopic third
16
third ventriculostomy
16
death late
12
failure endoscopic
12
failure successful
8
successful third
8
cerebrospinal fluid
8
third
7
failure
6

Similar Publications

Malignant ascites (MA), a common and serious complication of various cancers in the abdominal cavity, originates from the extensive infiltration, metastasis, and growth of cancer cells in or on the abdominal cavity, leading to abnormal accumulation of fluid in the abdominal cavity and the formation of MA. MA seriously reduces the quality of life of cancer patients, shortens their survival period, and generally has a poor prognosis. Modern medicine has developed various strategies for the treatment of MA, including targeted supportive treatment, diuretic treatment, abdominal paracentesis, surgical intervention, and intraperitoneal administration therapy.

View Article and Find Full Text PDF

Susac's syndrome is a rare inflammatory microangiopathy characterized by the triad of retinopathy, encephalopathy, and hearing loss. The syndrome causes recurrent microinfarcts in these organs, which in turn manifests with repeated attacks of visual field loss, hearing loss and tinnitus, and various brain syndromes. These often lead to the significant accumulation of disability over time, particularly if there is a delay or failure in diagnosis.

View Article and Find Full Text PDF

Background: The neonatal Sequential Organ Failure Assessment (nSOFA) score is an organ dysfunction score developed for predicting mortality risk in preterm neonates with proven late-onset neonatal sepsis (LONS) and necrotising enterocolitis. However, the utility of the nSOFA score in determining the risk of retinopathy of prematurity (ROP), bronchopulmonary dysplasia (BPD) or mortality in patients with suspected LONS is unknown.

Methods: We performed a dual-centre retrospective cohort study of preterm (gestational age <32 weeks) neonates suspected of LONS, from 2016 to 2020 at two neonatal intensive care units.

View Article and Find Full Text PDF

Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience.

Korean Circ J

November 2024

Department of Structural Heart Disease, National Center for Cardiovascular Disease & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China.

Background And Objectives: There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.

Methods: Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).

View Article and Find Full Text PDF

Mechanical failure of medical implants, especially in orthopedic poses a significant burden to the patients and healthcare system. The majority of the implant failures are diagnosed at very late stages and are of mechanical causes. This makes the diagnosis and screening of implant failure very challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!