A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and characterization of an infection inhibiting urinary catheter. | LitMetric

Catheter associated bacturia is common in hospitals and nursing homes. The objective of this study was to develop an infection inhibiting urinary catheter for prolonged use. Methods were established to add chlorhexidine digluconate (CHG) to a silicone elastomer and to compression mold the material to form a urinary catheter. CHG was randomly dispersed in the elastomer to be released through elution. Samples of the material, with CHG concentrations ranging from 1 to 4% by weight, were tested for in vitro release characteristics over a 28 day period and for in vivo toxicity over a 7 day period. Release profiles followed a common pattern for each concentration: an initial peak during the first 24 hours was followed by a subsequent decline. CHG amounts released into the saline medium were directly related to the CHG concentration of the samples; 4% samples released the largest amounts and 1% samples released the least amounts. Both 3% and 4% CHG by weight samples released measurable amounts of CHG throughout the entire observation period, whereas 1% CHG by weight samples were depleted after 9 days, and 2% CHG by weight samples were depleted after 19 days. No samples were found to be toxic during in vivo evaluations. These studies suggest that CHG bearing silicone rubber urinary catheters could resist surface colonization and infection for extended periods without toxicity.

Download full-text PDF

Source

Publication Analysis

Top Keywords

urinary catheter
12
samples released
12
chg weight
12
weight samples
12
chg
10
infection inhibiting
8
inhibiting urinary
8
samples
8
day period
8
amounts chg
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!