A respiratory catheter that is inserted through a peripheral vein and placed within the vena cava is being developed for CO2 removal in patients with acute exacerbations of chronic obstructive pulmonary disease (COPD). The catheter uses a rapidly pulsating balloon to enhance gas exchange. In this study, the CO2 removal performance of our catheter was assessed in acute sheep implants and compared with calf implants, primarily because sheep have cardiac outputs (CO) that are more comparable with human CO and lower than calves. Respiratory catheters (25 mL balloon, 0.17 m2) were inserted acutely in sheep (n = 2) and calves (n = 6) through the jugular vein and placed within the vena cava in two positions: spanning the right atrium (RA) and within the inferior vena cava (IVC). The postinsertion CO in the sheep ranged from 4.1 to 7.2 L/min compared with 6.2 to 15.5 L/min for the calves. The maximum CO2 removal rates (vCO2) were 297 ml/min/m2 (calf) and 282 ml/min/m2 (sheep) in the RA position and 240 ml/min/m2 (calf) and 248 ml/min/m2 (sheep) in the IVC position. The respective removal rates between animal models were not statistically different (p values > 0 .05 for all data sets). The dependence of the vCO2 on balloon pulsation was also not statistically different between the animal models.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2002495 | PMC |
http://dx.doi.org/10.1097/01.mat.0000074991.94234.b6 | DOI Listing |
Cureus
December 2024
Critical Care Medicine, NMC Specialty Hospital, Abu Dhabi, ARE.
A 50-year-old female presented with a 10-day history of progressive swelling and pain in the left lower extremity, ultimately diagnosed with deep vein thrombosis (DVT) and May-Thurner Syndrome (MTS). Initial ultrasound indicated thrombosis involving the left external iliac, femoral, and popliteal veins, among others. Blood tests revealed normocytic anemia, but thrombophilia screening and other blood markers were normal.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiovascular Medicine, Kyoto Chubu Medical Center, 25, Yagi-Ueno, Yagi-cho, Nantan City, Kyoto 629-0197, Japan.
Background: Constrictive pericarditis (CP) can arise from various causes, including post-operative degeneration, tuberculosis, and sequelae of pericarditis. Immunoglobulin (Ig) G4-related disease is a rare but recognized cause of CP. However, the specific mechanisms underlying these aetiologies and pathologies remain unclear.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiology, General Hospital Celle, Siemensplatz 4, Celle 29223, Germany.
Background: High-risk pulmonary embolism (PE) is associated with significant mortality. Thrombolysis is the therapy of choice, while interventional thrombectomy may be a helpful strategy in case of contraindications or failed thrombolysis. However, the procedure may be complicated by catheter-induced embolization of clots and/or haemodynamic compromise.
View Article and Find Full Text PDFJ Thromb Haemost
January 2025
Case Western Reserve University, School of Medicine, Department of Pharmacology, Cleveland, OH United States. Electronic address:
Background: Hypercoagulation and thrombin generation are major risk factors for venous thrombosis. Sustained thrombin signaling through PAR4 promotes platelet activation, phosphatidylserine exposure, and subsequent thrombin generation. A single-nucleotide polymorphism in PAR4 (rs2227376) changes proline to leucine extracellular loop 3 (P310L), which decreases PAR4 reactivity and is associated with a lower risk for venous thromboembolism (VTE) in a GWAS meta-analysis.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Cardiology, Umberto I Hospital, 84014 Nocera Inferiore, Italy.
Heart and lung sharing the same anatomical space are influenced by each other. Spontaneous breathing induces dynamic changes in intrathoracic pressure, impacting cardiac function, particularly the right ventricle. In intensive care units (ICU), mechanical ventilation (MV) and therefore positive end-expiratory pressure (PEEP) are often applied, and this inevitably influences cardiac function.