The success and safety of standard catheter radiofrequency ablation may be limited for ablation of atrial fibrillation and ventricular tachycardia. The aim of this study was to characterize and compare different cooled and noncooled catheter systems in terms of their specific lesion geometry, incidence of impedance rise, and crater and coagulum formation to facilitate appropriate catheter selection for special indications. The study investigated myocardial lesion generation of three cooled catheter systems (7 Fr, 4-mm tip): two saline irrigation catheters with a showerhead-type electrode tip (sprinkler) and a porous metal tip and an internally cooled catheter. Noncooled catheters (7 Fr) had a large tip electrode (8 mm) and a standard tip electrode (4 mm). RF energy was delivered on isolated porcine myocardium superfused with heparinized pig blood (37 degrees C) at power settings of 10-40 W. Both irrigated systems were characterized by a large lesion depth (8.1 +/- 1.6 mm) and a large lesion diameter (13.8 +/- 1.6 mm). In comparison, internally cooled lesions showed a similar lesion depth (8.0 +/- 1.0 mm), but a significantly smaller lesion diameter (12.3 +/- 1.2 mm,P = 0.04). Large tip lesions had a similar lesion diameter (14.5 +/- 1.6 mm), but a significantly smaller lesion depth (6.3 +/- 1.0 mm,P = 0.002) compared to irrigated lesions. However, lesion volume was not significantly different between the three cooled and the large tip catheter. To induce maximum lesion size, power requirements were three times higher for the irrigation systems and two times higher for the internally cooled and the large tip catheter compared to the standard catheter. Impedance rise was rarest with irrigated and large tip ablation. In case of impedance rise crater formation was a frequent observation (61-93%). Irrigated catheters prevented coagulum formation most effectively. Irrigated rather than internally cooled ablation appears to be most adequate for the induction of deep and long lesions at a low rate of impedance rise and thrombus formation. Large tip ablation may be feasible for the creation of long linear lesions, however, with an increased risk of thrombus formation.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1460-9592.2003.t01-1-00208.xDOI Listing

Publication Analysis

Top Keywords

impedance rise
16
internally cooled
16
lesion depth
12
depth +/-
12
lesion diameter
12
lesions lesion
12
lesion
11
cooled
8
cooled noncooled
8
specific lesion
8

Similar Publications

A previous study reported an increase in carotid-femoral pulse wave velocity (cfPWV) during an upright posture compared to the supine position, partly due to sympathetic activation. However, given that cfPWV is influenced by the transmural pressure (TMP) of the artery, which is elevated in the abdominal aorta in the seated posture due to increased hydrostatic pressure. Thus, it remains unclear whether this increased cfPWV reflects a true rise in arterial stiffness or is simply a result of the elevated TMP.

View Article and Find Full Text PDF

Hydrogel nanocomposites that respond to external stimuli and possess switchable electrical properties are considered as emerging materials with potential uses in electrical, electrochemical, and biological devices. This work reports the synthesis and characterization of thermo-responsive and electroconductive hydrogel nanocomposites based on poly(-isopropylacrylamide) (PNiPAAm) and gold nanoparticles (nanospheres-AuNPs and nanorods-AuNRs) using two different synthetic techniques. Method I involved γ-irradiation-induced crosslinking of a polymer matrix (hydrogel), followed by radiolytic formation of gold nanoparticles, while Method II included the chemical synthesis of nanoparticles, followed by radiolytic formation of a polymer matrix around the gold nanoparticles.

View Article and Find Full Text PDF

The need to optimize size, weight, and power of high-power microwave (HPM) systems has motivated the development of solid-state HPM sources, such as nonlinear transmission lines (NLTLs), which utilize gyromagnetic precession or dispersion to generate RF. One recent development implemented the NLTL as a pulse forming line (PFL) to form a nonlinear pulse forming line (NPFL) system that substantially reduced the system's size by eliminating the need for a separate PFL; however, matching standard loads can be challenging. This paper describes the development of a tapered NPFL using an exponentially tapered composite based ferrite core containing 60% nickel zinc ferrite (by volume) encased in polydimethylsiloxane (PDMS) and encapsulated in a 5% barium strontium titanate shell.

View Article and Find Full Text PDF

Fluidic feedback for soft actuators: an electronic-free system for sensing and control.

Bioinspir Biomim

December 2024

College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China.

The field of pneumatic soft robotics is on the rise. However, most pneumatic soft robots still heavily rely on rigid valves and conventional electronics for control, which detracts from their natural flexibility and adaptability. Efforts have focused on substituting electronic controllers with pneumatic counterparts to address this limitation.

View Article and Find Full Text PDF

The impact of N,1-dibenzyl-5-methyl-1H-pyrazol-3-carboxamide (BPC) on the carbon steel (CS) corrosion in hydrochloric acid (1 M) was studied in this work, considering concentration and temperature effects. Electrochemical investigation indicated that BPC functions as a mixed-type inhibitor. For an optimal BPC concentration of 125 ppm, the inhibition efficiency of 91.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!