Evaluation of a fully automated procalcitonin chemiluminescence immunoassay.

Clin Lab

Institut für Klinische Chemie und Laboratoriumsmedizin, Krankenhaus Dresden-Friedrichstadt, Dresden, Germany.

Published: March 2004

We evaluated a new fully automated microparticle immunoassay for procalcitonin (LIAISON BRAHMS PCT) in comparison with a previously established manual chemiluminescence assay from the same manufacturer (LUMItest PCT, BRAHMS AG). Procalcitonin (PCT) is an early and rather specific marker of systemic bacterial infection. In addition, the efficacy of antibiotic therapy can be monitored by sequential analysis of PCT values. This is why rapid and accurate determinations of PCT are urgently required by intensive care units. The aim of this study was to evaluate in a clinical set-up a new fully automated rapid PCT test. Analytical results are compared with results obtained by a previously introduced quantitative manual test. Intra-assay coefficients of variation (CV) were found in the range of 0.94 to 7.1% at concentrations between 0.46 and 97.2 microg/l. Over a time period of 27 days the inter-assay CV was found below 4.0% at concentrations of 1.93 and 14.29 microg/l and 9.9% at 0.40 microg/l. The functional sensitivity at a CV level of 20% was determined as 0.2 microg/l. Linearity could be demonstrated in a concentration range from 0 to 445 microg/l. When serum and plasma with EDTA, citrate or heparin anti-coagulation were analyzed in parallel, no systematic bias was found. A method comparison by regression analysis showed PCT values determined by both tests in very good agreement (r = 0.99). PCT concentrations in apparently healthy subjects (n =101) were below 0.58 microg/l in line with previously published results. Patients with sepsis (n = 43) or with infectious adult respiratory distress syndrome (ARDS) (n = 28) showed median values of 22.2 and 18.9 microg/l, respectively. In a clinical set-up the LIAISON Brahms PCT assay provided rapid and accurate PCT results supporting the early detection of severe sepsis, the differentiation between systemic bacterial infection and other inflammatory diseases, and the monitoring of antibiotic therapy in septic patients. The results of the new LIAISON BRAHMS PCT assay show an excellent concordance with the LUMItest PCT. The clinical information derived from the measurements is well comparable to the results obtained with the LUMItest PCT, too.

Download full-text PDF

Source

Publication Analysis

Top Keywords

pct
13
fully automated
12
liaison brahms
12
brahms pct
12
lumitest pct
12
systemic bacterial
8
bacterial infection
8
antibiotic therapy
8
analysis pct
8
pct values
8

Similar Publications

Objective: The aim of this study was to investigate the correlation between plateletcrit (PCT) and stages of hypertensive disease of pregnancy by comparing values in groups with healthy pregnancies, gestational hypertension [GHT], preeclampsia with proteinuria [PE + P] and severe preeclampsia with proteinuria [sPE + P]. The secondary aim was to investigate how proteinuria affects PCT values in these patients.

Materials And Methods: This was a retrospective cohort study.

View Article and Find Full Text PDF

Background: The rapid evolution of the COVID-19 pandemic and subsequent global immunization efforts have rendered early metabolomics studies potentially outdated, as they primarily involved non-exposed, non-vaccinated populations. This paper presents a predictive model developed from up-to-date metabolomics data integrated with clinical data to estimate early mortality risk in critically ill COVID-19 patients. Our study addresses the critical gap in current research by utilizing current patient samples, providing fresh insights into the pathophysiology of the disease in a partially immunized global population.

View Article and Find Full Text PDF

The cerebellum is activated by noxious stimuli and pathological pain but its role in noxious information processing remains unknown. Here, we show that in mice, cutaneous noxious electrical stimuli induced noradrenaline (NA) release from locus coeruleus (LC) terminals in the cerebellar cortex. Bergmann glia (BG) accumulated these LC-NA signals by increasing intracellular calcium in an integrative manner ('flares').

View Article and Find Full Text PDF

Genome editing using CRISPR-Cas systems is a promising avenue for the treatment of genetic diseases. However, cellular and humoral immunogenicity of genome editing tools, which originate from bacteria, complicates their clinical use. Here we report reduced immunogenicity (Red)(i)-variants of two clinically relevant nucleases, SaCas9 and AsCas12a.

View Article and Find Full Text PDF

Current assays fail to address breast cancer's complex biology and accurately predict treatment response. On a retrospective cohort of 1082 female breast tissues, we develop and validate mFISHseq, which integrates multiplexed RNA fluorescent in situ hybridization with RNA-sequencing, guided by laser capture microdissection. This technique ensures tumor purity, unbiased whole transcriptome profiling, and explicitly quantifies intratumoral heterogeneity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!