The generalized monitor unit (MU) calculation equation for the Varian enhanced dynamic wedge (EDW) is derived. The assumption of this MU calculation method is that the wedge factor of the EDW at the center of the field is a function of field size, the position of the center of the field in the wedge direction, and the final position of the moving jaw. The wedge factors at the center of the field in both symmetric and asymmetric fields are examined. The difference between calculated and measured wedge factors is within 1.0%. The method developed here is easy to implement. The only datum required in addition to the standard set of conventional physical wedge implementation data is the off-axis output factor for the open field in the reference condition. The off-center point calculation is also examined. For the off-center point calculation, the dose profile in the wedge direction for the largest EDW field is used to obtain the relative off-center ratio in any smaller wedge field. The accuracy of the off-center point calculation decreases when the point of calculation is too close to the field edge.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.1586269DOI Listing

Publication Analysis

Top Keywords

point calculation
16
center field
12
off-center point
12
wedge
9
field
9
generalized monitor
8
monitor unit
8
unit calculation
8
varian enhanced
8
enhanced dynamic
8

Similar Publications

Objectives: To conduct a meta-analysis of the diagnostic performance of non-contrast magnetic resonance pulmonary angiography (NC-MRPA) and ventilation-perfusion (V/Q) scintigraphy for the detection of acute pulmonary embolism (PE).

Materials And Methods: Systematic searches of electronic databases were conducted from 2000 to 2024. Primary outcomes were per-patient sensitivity and specificity of NC-MRPA and V/Q scintigraphy.

View Article and Find Full Text PDF

In order to solve the problem of logging calibration without a free pipe in the process of acoustic variable density logging and the subjective problem of the free pipe calibration method, this paper studies an attenuation rate calibration method based on acoustic variable density logging. Using the developed acoustic wave probe response relationship device and the acoustic wave probe calibration device, the response consistency of the receiving probe of the acoustic wave instrument and the frequency of the transmitting probe can be calibrated in the laboratory, and the response consistency and frequency calibration coefficient can be obtained. Through this coefficient, the acoustic wave attenuation rate can be derived.

View Article and Find Full Text PDF

Objective: Frailty has become an increasingly recognized perioperative risk stratification tool. While frailty has been strongly correlated with worsening surgical outcomes, the individual determinants of frailty have rarely been investigated in the setting of aortic disease. The aim of this study was to examine the determinants of an 11-factor modified frailty index (mFI-11) on mortality and postoperative complications in patients undergoing endovascular aortic aneurysm repair (EVAR).

View Article and Find Full Text PDF

Background: Psoriasis is a chronic disease with a prevalence of 3% in the general population. The high prevalence of psoriasis has prompted the study of its comorbidities in recent decades. However, no studies have ever analyzed comorbidity patterns including all chronic diseases in psoriatic patients.

View Article and Find Full Text PDF

The work aims to estimate natural greenhouse gas emissions from soils in the Sibari Coastal Plain (Southern Italy), to understand (i) the contribution in terms of the total amount of CO and CH emitted in non-volcanic areas, (ii) the relationship among emitted gas, land use, organic matter and tectonic structures, and (iii) their potential environmental implications. Data were elaborated with statistical and geostatistical methods to separate the different populations and obtain prediction and probability maps. Methane fluxes had values consistently below the detection limit (0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!