We evaluated spontaneous tumescence after penile prostheses implantation in a retrospective study. A total of 32 patients with three-piece hydraulic implants (17 Mentor Alpha I, 15 AMS Ultrex Plus) were enrolled. Consultation, personal interviews and questionnaires for both the patients and their partners provided the necessary information. The average follow-up period was 29 months. In total, 50 % of the patients reported spontaneous tumescence without activation of the implant and one further patient (3%) claimed full rigid spontaneous erections. General satisfaction with the prosthetic result was high at 91%. The following complications arose: one case of prosthesis infection, one case of mechanical failure, one case of cylinder dislocation and two cases of paraphimosis. A possible explanation for spontaneous tumescence after penile prosthesis implantation is the elevated preload of the compressed rather than destructed cavernous tissue. The artificial erection evoked by the prosthesis then takes the form of a normal physiological reaction and/or a good objective ridigity, and could account for the high patient satisfaction rate with three-piece hydraulic implants.

Download full-text PDF

Source
http://dx.doi.org/10.1038/sj.ijir.3900979DOI Listing

Publication Analysis

Top Keywords

spontaneous tumescence
16
three-piece hydraulic
12
penile prostheses
8
tumescence penile
8
total patients
8
hydraulic implants
8
spontaneous
5
tumescence implantation
4
implantation three-piece
4
hydraulic penile
4

Similar Publications

A wearable adaptive penile rigidity monitoring system for assessment of erectile dysfunction.

Microsyst Nanoeng

September 2024

School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230026, China.

Article Synopsis
  • Erectile dysfunction (ED) is common and requires monitoring of penile tumescence and rigidity during nighttime erections for accurate diagnosis, but existing devices are bulky and interfere with erections.
  • A new wearable system called WARM uses an elastic dual-ring sensor that doesn't apply active loads, allowing for precise tracking of erections without compromising comfort.
  • The WARM system has been tested for consistency against standard devices and supports uninterrupted monitoring during sleep, making it a promising solution for improving ED assessment.
View Article and Find Full Text PDF

Treatment of Refractory Ischemic Priapism: A Case Report and Literature Review.

Cureus

June 2023

Urology, Centro Medico Nacional 20 de Noviembre, Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado, Mexico City, MEX.

Recurrent priapism is a rare and poorly known entity. It is defined by recurrent episodes of painful erections that last less than four hours. The etiology is similar to that of ischemic priapism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!