Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: We sought to determine whether a dual-isotope imaging strategy (rest thallium 201/stress technetium 99m sestamibi) might be useful for assessing myocardial viability and residual ischemia in the infarct zone very early after reperfusion.
Methods And Results: Fifteen open-chest dogs had left anterior descending coronary artery occlusion for 60 minutes, followed by full reperfusion (group 1, n = 8) or reperfusion through a residual critical stenosis (group 2, n = 7). Tl-201 was injected at rest 45 minutes after reperfusion, and initial and 2-hour redistribution images were acquired. Tc-99m sestamibi was then injected during vasodilator stress, followed by imaging. Infarct size was similar in both groups (risk area, 21% +/- 4% vs 22% +/- 3%). Rest Tl-201 defect count ratios (left anterior descending coronary artery/left circumflex artery) were comparable (0.71 +/- 0.03 vs 0.74 +/- 0.02) and reflected infarct size. With vasodilation, Tc-99m sestamibi defect count ratio in group 1 (0.71 +/- 0.02) was comparable to rest Tl-201 and was significantly greater than in group 2 (0.62 +/- 0.02) with residual stenoses (P <.01). Although vasodilator Tc-99m sestamibi imaging unmasked the presence of residual stenoses, Tc-99m sestamibi uptake underestimated their functional severity (flow ratio, 0.38 +/- 0.03).
Conclusions: Dual-isotope imaging very early after reperfusion may have limited utility for detecting residual stenoses in the infarct zone. Underestimation of the flow disparity by Tc-99m sestamibi may make the detection of stenoses more difficult, and impaired flow reserve after ischemic insult may complicate the detection of fully reperfused segments.