Scintimammography is a relatively new, non-invasive diagnostic modality in the evaluation of breast cancer. The purpose of the current study was to review the existing literature on the accuracy of scintimammography in the diagnosis of breast cancer. A search of all articles published between 1st January 1967 and 31st December 1999 was conducted. A total of 64 unique studies were selected. Each scientific paper was reviewed for scientific merit by an epidemiologist, a surgeon and a surgical resident. Assessment of scientific merit was based on a scoring scheme developed for the study. The articles included in this review reported data on a total of 5340 patients assessed for breast cancer with scintimammography. The aggregated summary estimates on these patients were sensitivity: 85.2% and specificity: 86.6%. For patients with a palpable mass the sensitivity and specificity were 87.8 and 87.5%, respectively. For patients without a palpable mass the sensitivity was 66.8% and that for specificity was 86.9%. The results of this review have shown that scintimammography may be used effectively as an adjunct to mammography and physical examination in the diagnosis of breast cancer.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1023/A:1024417331304 | DOI Listing |
BMC Cancer
January 2025
Young Academy of Gynecologic Oncology (JAGO), Nord-Ostdeutsche Gesellschaft für Gynäkologische Onkologie (NOGGO), Berlin, Germany.
Background: The integration of immune checkpoint inhibitors (ICIs) into routine gynecologic cancer treatment requires a thorough understanding of how to manage immune-related adverse events (irAEs) to ensure patient safety. However, reports on real-world clinical experience in the management of ICIs in gynecologic oncology are very limited. The aim of this survey was to provide a real-world overview of the experiences and the current state of irAE management of ICIs in Germany, Switzerland, and Austria.
View Article and Find Full Text PDFBMC Cancer
January 2025
Division de la Recherche Clinique, Centre Jean PERRIN, 58 rue Montalembert, Clermont-Ferrand, 63011, France.
Background: Over the past twenty years, the post-cancer rehabilitation has been developed, usually in a hospital setting. Although this allows better care organization and improved security, it is perceived as stressful and restrictive by the "cancer survivor". Therefore, the transfer of benefits to everyday life is more difficult, or even uncertain.
View Article and Find Full Text PDFBreast Cancer
January 2025
Tepe Prime, MKA Breast Cancer Clinic, 06800, Ankara, Turkey.
Breast Cancer Res Treat
January 2025
Google Health, 1600 Amphitheatre Pkwy, Mountain View, CA, 94043, USA.
Purpose: Many breast centers are unable to provide immediate results at the time of screening mammography which results in delayed patient care. Implementing artificial intelligence (AI) could identify patients who may have breast cancer and accelerate the time to diagnostic imaging and biopsy diagnosis.
Methods: In this prospective randomized, unblinded, controlled implementation study we enrolled 1000 screening participants between March 2021 and May 2022.
Mol Biol Rep
January 2025
Department of Clinical Pathology, Faculty of Medicine, Alexandria University, Alexandria, Egypt.
Background: The identification of circulating potential biomarkers may help earlier diagnosis of breast cancer, which is critical for effective treatment and better disease outcomes. We aimed to study the role of circ-FAF1 as a diagnostic biomarker in female breast cancer using peripheral blood samples of these patients, and to investigate the relation between circ-FAF1 and different clinicopathological features of the included patients.
Methods And Results: This case-control study enrolled 60 female breast cancer patients and 60 age-matched healthy control subjects.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!