The reports of an increasing incidence of iatrogenic ectasia, the evolution of wavefront aberrometry, and the suggestion that the laser in situ keratomileusis flap could lead to unpredictable biomechanical corneal changes have renewed interest in surface ablation and have set the stage for the introduction of alternative photorefractive treatment modalities. The theoretical advantage of surface procedures, such as laser epithelial keratomileusis that preserve the epithelial button, stems from the repositioning of the epithelial flap over the laser-ablated corneal surface. This epithelial sheet is thought to act as a natural contact lens that decreases postoperative pain and haze formation. Epipolis laser in situ keratomileusis is an alternative modality of epithelial separation with the use of a device that features a blunt oscillating blade. This surgical approach does not require the use of alcohol for epithelial loosening.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00055735-200308000-00007 | DOI Listing |
J Ophthalmol
January 2025
Department of Ophthalmology, Isfahan Eye Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
To analyze patients' quality of life (QOL) after laser vision correction (LVC) from a worldwide literature review. Studies of prospective or cross-sectional design which evaluated QOL in patients after LVC and compared that to preoperative values or a matched group of emmetropes were included. The Web of Science, PubMed, Scopus, and ProQuest were searched for relevant articles published until February 2024.
View Article and Find Full Text PDFAnn Ital Chir
January 2025
Department of Ophthalmology, University Hospital of Udine, 33100 Udine, Italy.
Refractive surgery, which includes techniques such as Laser-Assisted In Situ Keratomileusis (LASIK), Photorefractive Keratectomy (PRK) and Small Incision Lenticule Extraction (SMILE), has revolutionized ophthalmology by offering advanced solutions for vision correction. However, the choice of the technique to be used in the individual patient is highly dependent on a thorough preoperative evaluation. This retrospective study aims to investigate how preoperative parameters, including corneal thickness, topography, and refraction, affect long-term post-operative clinical outcomes.
View Article and Find Full Text PDFConventional laser micromachining technologies rely on trial-and-error optimization to obtain precise surface geometry. In this study, we present a laser micromachining setup that enables the preparation of the desired surface geometry without the need for parameter exploration. The setup consists of a laser scanning system, a coaxial imaging system, a paraxial laser line projector, and a three-axis stage.
View Article and Find Full Text PDFSci Rep
January 2025
Xinqiao Hospital, Army Medical University, 183th, Xinqiao Street, Shapingba District, Chongqing, China.
The purpose of this study was to evaluate the stability of small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK) when ascending from near sea level to an altitude of 3874 m. The visual acuity (VA), intraocular pressure (IOP), spherical equivalent refraction (SER) and biometric parameters of 20 normal subjects (40 eyes, controls) and 36 subjects who underwent corneal refractive surgery (35 eyes with SMILE and 36 eyes with LASIK) were examined in Chongqing (C, 500 m above sea level) and 7-10 days after a collective travel to Shigatse (S, 3874 m above sea level). SER and corneal thickness (CT) were choosed as main indicators of the stability of corneal refractive surgery at high altitude.
View Article and Find Full Text PDFAnal Chem
January 2025
College of Chemistry and Material Science, Northwest University, Xi'an 710127, China.
With rapid, energy-intensive, and coal-fueled economic growth, global air quality is deteriorating, and particulate matter pollution has emerged as one of the major public health problems worldwide. It is extremely urgent to achieve carbon emission reduction and air pollution prevention and control, aiming at the common problem of weak and unstable signals of characteristic elements in the application of laser-induced breakdown spectroscopy (LIBS) technology for trace element detection. In this study, the influence of the optical fiber collimation signal enhancement method on the LIBS signal was explored.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!