[Post-operatory biometry and refraction results estimated and refraction surprises--clinical study].

Oftalmologia

Clinica de Oftalmologie Ama Optimex Bucureşti.

Published: January 2004

Preoperative biometry has a major influence on the success or failure of IOL implantation procedures. The paper wishes to demonstrate the significance of this manoeuvre for the refraction and visual outcome and for the postoperative satisfaction rate of the patients. The clinical study has rulled out for one year period and a number of 239 patients suffered a IOL implantation procedure (cataract or lens extraction for refractive purposes). The preoperative biometry was always necessary. We used one of the existing IOL power calculation formula (SRK II, SRK T, Holladay). The surgeon decided about the IOL power, always after discussing with the patient their postoperative refractive expectations. The postoperative refraction was, in the majority of cases, the estimated refraction and the errors were similar with those from the literature. Refractive surprises of several diopters were registered in high myopic and hyperopic eyes or in cases of coexisting ocular diseases which have modified the anatomical parameters of the eye. In conclusion, small errors in calculation can have large effects on visual outcome. This problem will be solved in the future, because the field is evolving rapidly driven by a new understanding of the anatomy of the eye and new hardware for measuring that anatomy.

Download full-text PDF

Source

Publication Analysis

Top Keywords

estimated refraction
8
preoperative biometry
8
iol implantation
8
visual outcome
8
iol power
8
refraction
5
[post-operatory biometry
4
biometry refraction
4
refraction estimated
4
refraction surprises--clinical
4

Similar Publications

Purpose: We analyzed intraocular lens (IOL) power calculation in a series of patients with a zero diopter power implant. The idea was to bypass the Estimated Lens Plane (ELP), an important variable in normal IOL calculation.

Setting: Large multi-center group practice.

View Article and Find Full Text PDF

We theoretically calculate the coupling loss between single-mode fibers (SMFs) and polymer optical waveguides with different refractive index profiles. Temperature resistance is one of the concerns when integrating polymer optical waveguides near the electronics and photonics chips where they are highly likely to dissipate heat. Hence, the calculation focuses on the core size variations due to changes in operating temperature.

View Article and Find Full Text PDF

Hollow-core optical fiber (HCF) gas cells are an attractive option for many applications including metrology and non-linear optics due to the enhanced gas-light interaction length in a compact and lightweight format. Here, we report the first demonstration and characterization of a selectively pressurized, hermetically sealed hollow-core fiber-based gas cell, where the core is filled with a higher gas pressure than the cladding to enhance the optical performance. This differential gas pressure creates a gas-induced differential refractive index (GDRI) that is shown to enable significant modification of the HCF's optical performance.

View Article and Find Full Text PDF

This report explores the prevalence of keratoconus in a population-based cohort of adults aged 40 or older according to ten different definitions. All Rotterdam Study participants with reliable Pentacam scans and no prior corneal refractive surgery were cross-sectionally analysed (n = 2660). First, we applied a novel evidence-based definition.

View Article and Find Full Text PDF

Purpose: To evaluate the incidence, refractive error (RE) association, and distribution of atraumatic rhegmatogenous retinal detachment (RRD) in U.S. military service members (SMs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!