We investigated the regional cerebral blood flow (rCBF) in 8 patients with Parkinson disease (PD) with cognitive impairment (age; 64-82 years, Mini-Mental State Examination score = MMSE score; 22-6 points, Yahr stage; III-V), with the standard transaxial images and the Z-score images using the three-dimensional stereotactic surface projections (3D-SSP) of 123I-IMP SPECT. A contrast database was created by averaging extracted database sets of the contrast group (numbers; 14 cases, age; 64-82 years, MMSE score; > or = 29 points). The regions of the perfusion reduction shown on the standard transaxial images were similarly demonstrated on the Z-score images in 6 of the 8 patients, and only the Z-score images demonstrated definite regions of perfusion reduction in remaining 2 patients. Both the standard transaxial and Z-score images demonstrated the perfusion reduction in the temporo-parietal regions in all of the patients, and the Z-score images but not the standard transaxial ones detected the reduction in the posterior cingulate gyrus and precuneus in 3 patients. 3D-SSP images of 123I-IMP SPECT are thus more sensitive in detecting rCBF of the medial aspect of the parietal cortex than the standard transaxial images, and can be used as a diagnostic tool to objectively evaluate the cognitive function of PD patients.

Download full-text PDF

Source

Publication Analysis

Top Keywords

standard transaxial
20
z-score images
20
123i-imp spect
12
transaxial images
12
perfusion reduction
12
images demonstrated
12
images
9
cerebral blood
8
blood flow
8
three-dimensional stereotactic
8

Similar Publications

Performance Characteristics of a New Generation 148-cm Axial Field-of-View uMI Panorama GS PET/CT System with Extended NEMA NU 2-2018 and EARL Standards.

J Nucl Med

December 2024

Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China

Article Synopsis
  • The uMI Panorama GS PET/CT system is a new advanced imaging scanner designed to provide high sensitivity and excellent image resolution for medical diagnosis.
  • The study evaluates the system's performance based on established standards, focusing on parameters like spatial resolution, count rate performance, and sensitivity, using various testing methodologies.
  • Results showed impressive spatial resolutions below 3mm, high sensitivity rates, and good image quality with compliance to both NEMA and EARL guidelines, indicating the system's effectiveness for clinical use.
View Article and Find Full Text PDF

A machine learning algorithm for creating isotropic 3D aortic segmentations from routine cardiac MR localizers.

Magn Reson Imaging

January 2025

Institute of Cardiovascular Science, University College London, London WC1N 1DZ, United Kingdom; Barts Heart Centre, St. Bartholomew's Hospital, London EC1A 7BE, United Kingdom. Electronic address:

Article Synopsis
  • The study addresses the challenge of accurately identifying and measuring aortic aneurysms, which is crucial but often limited by the time-consuming nature of high-resolution 3D CMR sequences used for assessment.
  • Researchers developed a 3D U-Net that can create detailed 3D segmentations of the aorta from standard 2D images with lower resolution, enhancing the efficiency of aortic assessments in clinical and population studies.
  • The results showed that the new U-Net model produced 93% clinically suitable segmentations and achieved a high DICE score of 0.9, matching the accuracy of traditional high-resolution methods, indicating its potential for reliable clinical use.
View Article and Find Full Text PDF

Background: Coronary microvascular dysfunction is prevalent in women with signs and symptoms of ischemia but no obstructive coronary artery disease (CAD) and is associated with an adverse prognosis. Elevated pericardial fat volume predicts adverse cardiac events, but mechanistic pathways of the association are not well understood.

Methods: 118 women enrolled in the NHLBI-sponsored Women's Ischemia Syndrome Evaluation-Coronary Vascular Dysfunction study with suspected coronary microvascular dysfunction but no obstructive CAD underwent adenosine stress 1.

View Article and Find Full Text PDF

The uMI Panorama is a novel PET/CT system using silicon photomultiplier and application-specific integrated circuit technologies and providing exceptional spatial and time-of-flight (TOF) resolutions. The objective of this study was to assess the physical performance of the uMI Panorama in accordance with the National Electrical Manufacturers Association (NEMA) NU 2-2018 standard. Spatial resolution, sensitivity, count rate performance, accuracy, image quality, and TOF resolution were evaluated in accordance with the guidelines outlined in the NEMA NU 2-2018 standard.

View Article and Find Full Text PDF

Trauma, both penetrating and blunt, consists of a significant percentage of surgical admissions in Caribbean hospitals. Due to financial constraints, ideal resources for optimal surgical management are not always available. Despite these disadvantages, successful outcomes for complex, emergent cases are achieved through a combination of timely clinical assessment, intervention, and ingenuity in using the resources at hand.

View Article and Find Full Text PDF