  • The study evaluates how well changes in visual acuity can be distinguished from measurement errors using established test-retest variability (TRV) data.
  • Researchers simulated varying visual acuity challenges in normal subjects to assess sensitivity and specificity based on TRV criteria.
  • Results showed that changes of 0.2 logMAR or greater could be reliably identified, but smaller changes (0.1 logMAR) were often misclassified, suggesting that while high specificity can be achieved with TRV data, sensitivity remains a challenge.

Article Abstract

Purpose: To determine the sensitivity to change and specificity achieved when published test-retest variability (TRV) data are used to determine whether measured changes in ETDRS logarithm of the minimum angle of resolution (logMAR) visual acuity reflect true clinical change or are attributable to measurement error alone.

Methods: Various degrees of change in visual acuity were simulated in a group of normal subjects by adjusting test difficulty through manipulation of viewing distance. Sensitivity to simulated change and specificity were determined with change criteria derived from published Bland-Altman 95% ranges for TRV.

Results: The relationship between viewing distance and measured acuity was as predicted theoretically. Simulated acuity change of 0.2 logMAR (two lines of letters) or greater can be reliably distinguished from no change (both sensitivity and specificity >95%) with the ETDRS chart, but a change of 0.1 logMAR or less cannot.

Conclusions: The use of 95% ranges for TRV to establish the smallest measured visual acuity change that can be reliably detected ensures a high specificity but does not take account of sensitivity. Use of change criteria derived from published 95% ranges results in a sensitivity of approximately 50% (assuming identical levels of TRV). Sensitivity may be improved by using a change criterion that is smaller than the minimum change sought, providing the change criterion is still at least as large as the 95% range for TRV, so that specificity is maintained. Reducing TRV allows smaller changes in acuity to be reliably detected.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.02-1100DOI Listing

Publication Analysis

Top Keywords

visual acuity
16
change
14
95% ranges
12
clinical change
8
logmar visual
8
sensitivity change
8
change specificity
8
viewing distance
8
change criteria
8
criteria derived
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!