Effectiveness of composite cure associated with different curing modes of LED lights.

Oper Dent

Department of Restorative Dentistry, Faculty of Dentistry, National University of Singapore, Republic of Singapore.

Published: October 2003

This study compared the effectiveness of cure of two LED (light-emitting diodes) lights (Elipar FreeLight [FL], 3M-ESPE; GC e-Light [EL], GC) to conventional (Max [MX], Dentsply-Caulk [control]), high intensity (Elipar TriLight [TL], 3M-ESPE) and very high intensity (Astralis 10 [AS], Ivoclar Vivadent) halogen lights. The 10 light-curing regimens investigated were: FL1 400 mW/cm2 [40 seconds], FL2 0-400 mW/cm2 [12 seconds] --> 400 mW/cm2 [28 seconds], EL1 750 mW/cm2 [10 pulses x 2 seconds], EL2 350 mW/cm2 [40 seconds], EL3 600 mW/cm2 [20 seconds], EL4 0-600 mW/cm2 [20 seconds] --> 600 mW/cm2 [20 seconds], TL1 800 mW/cm2 [40 seconds], TL2 100-800 mW/cm2 [15 seconds] --> 800 mW/cm2 [25 seconds], AS1 1200 mW/cm2 [10 seconds], MX 400 mW/cm2 [40 seconds]. Effectiveness of cure with the different modes was determined by measuring the top and bottom surface hardness (KHN) of 2-mm thick composite (Z100, [3M-ESPE]) specimens using a digital microhardness tester (n=5, load=500 g; dwell time=15 seconds). Results were analyzed using one-way ANOVA/Scheffe's post-hoc test and Independent Samples t-test (p<0.05). At the top surface, the mean KHN observed with LED lights ranged from 55.42 +/- 1.47 to 68.54 +/- 1.46, while that of halogen lights was 62.64 +/- 1.87 to 73.14 +/- 0.97. At the bottom surface, the mean KHN observed with LED and halogen lights ranged from 46.90 +/- 1.73 to 66.46 +/- 1.18 and 62.26 +/- 1.93 to 70.50 +/- 0.87, respectively. Significant differences in top and bottom KHN values were observed between different curing regimens for the same light, and between LED and halogen lights. Although curing with most modes of EL resulted in significantly lower top and bottom KHN values than the control, no significant difference was observed for the different modes of FL. Hence, the effectiveness of composite cure with LED LCUs is product dependent.

Download full-text PDF

Source

Publication Analysis

Top Keywords

mw/cm2 [40
16
[40 seconds]
16
mw/cm2
13
seconds]
13
400 mw/cm2
12
seconds] -->
12
mw/cm2 [20
12
[20 seconds]
12
effectiveness cure
8
high intensity
8

Similar Publications

From the severe acute respiratory syndrome coronavirus in 2003 to the severe acute respiratory syndrome coronavirus 2 in 2019, coronavirus has seriously threatened human health. Electromagnetic waves not only own high penetration and low pollution but also can physically resonate with the virus. Several studies have demonstrated that electromagnetic waves can inactivate viruses efficiently.

View Article and Find Full Text PDF

A set of nCN/WO composites was synthesized through a simple thermal treatment for gold recovery from the simulated effluent of a non-cyanide-based plating bath. The obtained results exhibited that all nCN/WO composites demonstrated a higher photocatalytic activity for gold recovery than their pristine components due to the formation of nanocomposites which paved a convenient pathway for charge transfer. Among all synthesized composites, the 5.

View Article and Find Full Text PDF

Our extensive basic research on photodynamic therapy (PDT) application in models of intracranial malignant astrocytoma led to its clinical application for intracranial malignant astrocytoma in Japan. Having considered the safety and effectiveness of this pathology, we initiate a first-in-human clinical study of PDT for spinal cord malignant astrocytoma. This study has an open-label, single-arm design.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on dissimilar laser welding of AISI 1060 carbon steel and Duplex Stainless Steel 2205, using both experimental and numerical methods to analyze the impact of welding parameters.
  • The increase in laser power significantly influenced the melt pool depth, which rose from 0.4 mm to 1.4 mm when power was ramped up from 250 to 450 W, and the resultant microstructure varied between the two materials with distinct solidification patterns.
  • Tensile test results indicated that the carbon steel side exhibited brittle fracture, while the Duplex Stainless Steel showed a ductile fracture, highlighting the differing mechanical properties due to their respective microstructures and the transition towards ductility with increased laser energy density.
View Article and Find Full Text PDF

Light-curing of restorative composite through milled and 3D-printed full-contour zirconia for adhesive luting.

Dent Mater

January 2025

KU Leuven, Department of Oral Health Sciences, BIOMAT & UZ Leuven, Dentistry, Kapucijnenvoer 7, 3000 Leuven, Belgium. Electronic address:

Objectives: To evaluate the effect of different zirconia compositions and manufacturing processes on the light irradiance (LI), to measure the degree of conversion (DC) of solely light-curing restorative composite underneath these zirconia grades and to evaluate the respective zirconia microstructures.

Methods: Six dental zirconia grades (GC HT, GC UHT [GC]; Katana HT, Katana UTML [Kuraray Noritake]; Lava Esthetic, Lava Plus [3 M Oral Care]) were cut and sintered per manufacturer instructions. One 3D-printed zirconia grade (XJet [XJET]) was prepared according to previous research.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!