A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical implementation of an automated planning system for gamma knife radiosurgery. | LitMetric

Purpose: To evaluate an automated treatment planning system for gamma knife radiosurgery. This planning system was developed in our clinic and is now in routine clinical use. The system simultaneously optimizes the shot sizes, locations, and weights. It also guides the user in selecting the total number of radiation shots.

Methods And Materials: We assessed the clinical significance of the automated system by comparing an optimized plan with a manual plan for 10 consecutive patients treated at our gamma knife facility. Each treatment plan was analyzed using dose-volume histograms in conjunction with the conformity index, the minimum target dose, and the integral normal tissue dose.

Results: On average, the treatment plan produced by the inverse planning tool provided an improved conformity index, a higher minimum target dose, and a reduced volume of the 30% isodose line as compared to the corresponding plan developed by an experienced physician. An optimized treatment plan can typically be produced in 10 min or less.

Conclusions: The automated planning system consistently provides a high-quality treatment plan while reducing the time required for gamma knife treatment planning.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0360-3016(03)00440-1DOI Listing

Publication Analysis

Top Keywords

planning system
16
gamma knife
16
treatment plan
16
automated planning
8
system gamma
8
knife radiosurgery
8
treatment planning
8
minimum target
8
target dose
8
plan
7