We carried out clinical and basic studies of the Directigen Lateral Flow RSV (Becton, Dickinson and Company, USA), a rapid test kit that detects respiratory syncytial virus (hereinafter referred to as "RSV") antigens based on immunochromatography. For the clinical study, 103 nasopharyngeal aspirates from patients with acute respiratory infections were used to evaluate the kit. Compared to the cell culture method, the Directigen Lateral Flow RSV showed a sensitivity of 100% (16/16) and a specificity of 94.3% (82/87), and an agreement rate of 95.1% (98/103). When compared to conventional testing kits, we found that the total agreement rate with the Directigen RS (Nippon Becton Dickinson and Company) was 88.3% (91/103) and with RSV TestPack (Dainabot Co., Ltd.) was 91.3% (94/103). The detection limit of the Directigen Lateral Flow RSV was 2 x 10(3) PFU/ml for both RSV subgroups A and B. In the crossreactivity test, only RSV was found positive. No other microorganisms were crossreactive. We also studied storage stability of nasopharyngeal aspirates and found that stability was not affected by storage at room and refrigerator temperatures for 14 days. Taken all together, the Directigen Lateral Flow RSV is useful for the diagnosis of RSV infection in a clinical setting because its performance is equivalent to conventional testing kits and is easy to use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11150/kansenshogakuzasshi1970.77.443 | DOI Listing |
J Virol Methods
May 2013
Department of Pathology & Laboratories, Nassau University Medical Center, East Meadow, NY, USA.
Sofia, a novel, fluorescent lateral-flow immunoassay was compared with two conventional colorimetric assays, Quickvue Influenza A+B and Directigen FLU A+B, to identify influenza viral antigen from patient nasopharyngeal specimens. A total of 118 frozen original influenza-positive specimens and 57 prospective specimens were examined. Using rt-PCR as a referee assay, sensitivity values (%) for influenza A/B of 80.
View Article and Find Full Text PDFDiagn Microbiol Infect Dis
October 2008
Children's Mercy Hospitals and Clinics, Kansas City, MO 64157, USA.
The BD Directigen EZ RSV (BD) assay and the Binax NOW RSV (BN) assays are lateral flow immunochromatographic assays used in the rapid diagnosis of respiratory syncytial virus (RSV) infection. A prospective study was undertaken to compare the performance characteristics of the BD and BN assays using 99 fresh nasopharyngeal aspirate specimens from children. All specimens were cultured by tube cultures and R-mix shell vials.
View Article and Find Full Text PDFJ Clin Microbiol
August 2004
Division of Infectious Disease, Children's Hospital of Eastern Ontario, 401 Smyth Rd., Ottawa, Ontario K1H 8L1, Canada.
Rapid respiratory syncytial virus (RSV) diagnosis is vital to the prevention of nosocomial RSV infections. We evaluated a new rapid lateral-flow RSV immunoassay, the QuickLab RSV test, that requires use of only one reagent. We compared QuickLab to the Directigen RSV (DIR) assay, which requires six reagents, and direct fluorescent antibody (DFA) testing.
View Article and Find Full Text PDFWe carried out clinical and basic studies of the Directigen Lateral Flow RSV (Becton, Dickinson and Company, USA), a rapid test kit that detects respiratory syncytial virus (hereinafter referred to as "RSV") antigens based on immunochromatography. For the clinical study, 103 nasopharyngeal aspirates from patients with acute respiratory infections were used to evaluate the kit. Compared to the cell culture method, the Directigen Lateral Flow RSV showed a sensitivity of 100% (16/16) and a specificity of 94.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!