Purpose: To investigate the prognostic implications of conduction defects in subjects without proven coronary artery disease who had been referred for stress echocardiography.
Methods: The study sample consisted of 1230 patients (574 men and 656 women; mean [+/- SD] age, 63 +/- 10 years) who underwent stress echocardiography with dipyridamole (n = 780) or dobutamine (n = 450) to evaluate suspected coronary artery disease. A summary wall motion score (on a 1 to 4 scale) was calculated. Patients were followed for a mean of 41 +/- 27 months; mortality was the only endpoint.
Results: Four hundred and twenty patients (34%) had intraventricular conduction defects on a resting electrocardiogram (173 with complete left bundle branch block, 98 with isolated right bundle branch block, 43 with right bundle branch block with left anterior hemiblock, and 106 with left anterior hemiblock). Ischemia at stress echo (new or worsening of preexisting wall motion abnormality) was found in 250 patients (20%). There were 56 deaths during follow-up; 138 patients underwent revascularization and were censored. Multivariate predictors of mortality were resting wall motion score index (hazard ratio [HR] = 6.0 per unit increase; 95% confidence interval [CI]: 2.3 to 16; P <0.0001), ischemia at stress echo (HR = 3.9; 95% CI: 2.2 to 6.7; P <0.0001), age >65 years (HR = 3.2; 95% CI: 1.7 to 5.9; P <0.0001), hypertension (HR = 1.8; 95% CI: 1.1 to 3.2; P = 0.03), and right bundle branch block with left anterior hemiblock (HR = 3.7; 95% CI: 1.8 to 7.5; P <0.0001). The other three forms of intraventricular conduction defects (left bundle branch block, isolated complete right bundle branch block, and left anterior hemiblock) were not associated with mortality in multivariate analyses, or among the 980 patients who did not have ischemia.
Conclusion: Right bundle branch block with left anterior hemiblock is an independent predictor of mortality in patients with suspected coronary artery disease undergoing stress echocardiography, whereas isolated right bundle branch block is associated with outcomes similar to those observed in patients with no conduction defects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0002-9343(03)00239-0 | DOI Listing |
Biomater Adv
December 2024
Key Laboratory for Ultrafine Materials of Ministry of Education, Frontiers Science Center for Materiobiology and Dynamic Chemistry, Engineering Research Center of Biomedical Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237, PR China. Electronic address:
Spinal cord injury (SCI) results in electrophysiological and behavioral dysfunction. Electrical stimulation (ES) is considered to be an effective treatment for mild SCI; however, ES is not applicable to severe SCI due to the disruption of electrical conduction caused by tissue defects. Therefore, the use of conductive materials to fill the defects and restore electrical conduction in the spinal cord is a promising therapeutic strategy.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
School of Materials Science and Engineering, Tianjin Key Lab for Rare Earth Materials and Applications, Nankai University, Tianjin 300350, China.
For silicon-based devices using dielectric oxides doped with rare earth ions, their electroluminescence (EL) performance relies on the sufficient carrier injection. In this work, the atomic GaO layers are inserted within the Er-doped GeO nanofilms fabricated by atomic layer deposition (ALD). Both Ga(CH) and Ga(CH) could realize the ALD growth of GaO onto the as-deposited GeO nanofilm with unaffected deposition rates.
View Article and Find Full Text PDFNat Genet
January 2025
Telemachus and Irene Demoulas Family Foundation Center for Cardiac Arrhythmias, Massachusetts General Hospital, Boston, MA, USA.
To broaden our understanding of bradyarrhythmias and conduction disease, we performed common variant genome-wide association analyses in up to 1.3 million individuals and rare variant burden testing in 460,000 individuals for sinus node dysfunction (SND), distal conduction disease (DCD) and pacemaker (PM) implantation. We identified 13, 31 and 21 common variant loci for SND, DCD and PM, respectively.
View Article and Find Full Text PDFA A Pract
January 2025
Integrated Anesthesia Associates, Department of Anesthesia, Hartford Hospital, Hartford, Connecticut.
Inappropriate sinus tachycardia (IST) presents challenges in diagnosis and treatment due to its unclear etiology and limited therapeutic options. This case report explores the use of continuous stellate ganglion block (CSGB) as a potential treatment avenue. A 23-year-old woman with refractory IST underwent several CSGB placements, resulting in prolonged symptom relief and decreased median heart rate.
View Article and Find Full Text PDFIndian Pacing Electrophysiol J
December 2024
Intermountain Heart Institute - Utah Valley Hospital, Salt Lake City, Utah, USA.
Introduction: The advancement of medical technology has introduced leadless pacemakers (LPMs) as a significant innovation in cardiac pacing, offering potential advantages over traditional ventricular transvenous pacemakers. This report explores the application of LPMs in two patients with complex valvular histories, particularly those with mechanical tricuspid valves.
Case Reports: The first case involves a 60-year-old male with a history of rheumatic heart disease and triple valve replacement who developed a high-grade AV block.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!