Exercise heart rate variability of older women in relation to level of physical activity.

J Gerontol A Biol Sci Med Sci

Groupe de Recherche Cardiovasculaire, Unité de Biologie et Médecine du Sport, CHU Pontchaillou, Rennes, France.

Published: July 2003

The purpose of this study was to determine the effect of the level of physical activity in older women on heart rate (HR) response to its neural control at rest and during exercise by using heart rate variability (HRV) analysis. Electrocardiogram (ECG) was recorded in 3 (low, moderately, and highly) active groups of older women at rest and during submaximal exercise. Spectral HRV indexes were obtained from the ECG signal. At rest, highly active subjects have low HR without any alteration of HRV. During incremental submaximal exercise, parasympathetic modulations of HR decreased only in the highly active subjects (p <.01) without any alteration of HR, compared with the other groups. In older women, the effects of the level of physical activity on HR and HRV are dissociated. Quite a high level of physical training induces a higher sensitivity of sinus node response to the autonomic nervous system during exercise.

Download full-text PDF

Source
http://dx.doi.org/10.1093/gerona/58.7.b585DOI Listing

Publication Analysis

Top Keywords

heart rate
12
older women
12
highly active
12
exercise heart
8
rate variability
8
level physical
8
physical activity
8
submaximal exercise
8
active subjects
8
exercise
4

Similar Publications

α-Cyclodextrin (αCD), a cyclic hexasaccharide composed of six glucose units, is not digested in the small intestine but is completely fermented by gut microbes. Recently, we have reported that αCD supplementation for nonathlete men improved their 10 km biking times. However, the beneficial effects of αCD on exercise are not yet fully understood.

View Article and Find Full Text PDF

Endovascular treatment of postoperative aortic coarctation aneurysms-a single center experience.

Front Cardiovasc Med

December 2024

Department of Cardiology, University Hospital 'St. Ekaterina', Medical University of Sofia, Sofia, Bulgaria.

Background: Formation of local type aortic aneurysm years after surgical repair of coarctation (CoA) occurs in 10% of patients independent of the surgical technique and is a potentially life-threatening condition if left untreated with a high risk of aortic rupture. Redo open surgery is associated with 14% in-hospital mortality and a high risk of complications. Endovascular treatment appears to be a feasible alternative with a high success rate and low morbidity and mortality, but data concerning long-term results is still mandatory.

View Article and Find Full Text PDF

Resting-state EEG measures have shown potential in distinguishing individuals with PTSD from healthy controls. ERP components such as N2, P3, and late positive potential have been consistently linked to cognitive abnormalities in PTSD, especially in tasks involving emotional or trauma-related stimuli. However, meta-analyses have reported inconsistent findings.

View Article and Find Full Text PDF

Transcatheter Aortic Valve-in-Valve Implantation with Newer Generation Evolut Valve by Size of Failed Bioprosthesis.

Anatol J Cardiol

January 2025

Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA ; Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA.

Background: To evaluate the clinical outcomes of valve-in-valve transcatheter aortic valve replacement (ViV TAVR) with newer-generation self-expanding Evolut valves according to the size of the failed surgical bioprosthesis.

Methods: This single-center retrospective study evaluated consecutive patients undergoing ViV TAVR with the Evolut Pro/Pro+/Fx between 2018 and 2022. These patients were compared based on the true internal diameter (ID) of the failed bioprosthesis, specifically ≤19 mm (small group) vs.

View Article and Find Full Text PDF

Background: Type 2 diabetes mellitus (T2DM) patients with small-diameter stents (SDS), that are equal to or less than 2.5 mm in diameter, face increased risks of restenosis and complications. This study aimed to evaluate the 1-year follow-up to assess the rate of major adverse cardiac events (MACE) and bleeding risk between ticagrelor and clopidogrel in T2DM patients after SDS implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!