Object: Recently, expandable cages for vertebral body replacement in the cervical spine have been developed. The purpose of this study was to compare the biomechanical properties of expandable cages with those of a tricortical iliac crest graft and a nonexpandable cage.

Methods: Forty human cervical spines (C3-5) were tested in flexion, extension, axial rotation, and lateral bending. First all motion segments were evaluated intact. After corpectomy of C4 the spines were divided into five groups of eight and the following stabilization techniques were used: 1) autologous iliac crest bone graft; 2) mesh titanium cage; 3) anterior distraction device; 4) Synex-C titanium; and 5) Synex-C PEEK. Additionally, anterior plating and anterior plating plus posterior screw/rod fixation were applied. Stiffness, range of motion, and neutral and elastic zones were determined. In comparison with the intact motion segment all implants significantly increased stiffness in flexion and bending, but decreased stiffness in extension. There were no biomechanical differences between the nonexpandable and expandable cages. Furthermore, there were no biomechanical differences between the tricortical iliac crest graft and the cages, except for Synex-C in rotation. Additional anterior plating significantly increased biomechanical stiffness in all test modes; particularly in rotation mode, combined anterior-posterior stabilization increased stiffness by up to 102% compared with anterior plating alone.

Conclusions: In comparison to a tricortical iliac crest bone graft and a nonexpandable cage, expandable cages have no biomechanical advantages. Due to the low extension and rotational stiffness, none of the implants can be recommended as a stand-alone device. Additional anterior plating increased biomechanical stability adequately. Therefore, additional posterior stabilization should only be considered in cases of severe rotational instability of the cervical spine.

Download full-text PDF

Source
http://dx.doi.org/10.3171/spi.2003.99.1.0091DOI Listing

Publication Analysis

Top Keywords

expandable cages
20
anterior plating
20
iliac crest
16
cervical spine
12
tricortical iliac
12
cages vertebral
8
vertebral body
8
body replacement
8
replacement cervical
8
crest graft
8

Similar Publications

Semiconducting Electrides Derived from Sodalite: A First-Principles Study.

ACS Omega

January 2025

Department of Mechanical Engineering and Engineering Science, University of North Carolina at Charlotte, Charlotte, North Carolina 28223, United States.

Electrides are ionic crystals, with electrons acting as anions occupying well-defined lattice sites. These exotic materials have attracted considerable attention in recent years for potential applications in catalysis, rechargeable batteries, and display technology. Among this class of materials, electride semiconductors can further expand the horizon of potential applications due to the presence of a band gap.

View Article and Find Full Text PDF

Guest Segregation in Heteromeric Multicage Systems.

J Am Chem Soc

January 2025

Department of Chemistry and Chemical Biology, TU Dortmund University, Otto-Hahn Str. 6, 44227 Dortmund, Germany.

Dynamically interconvertible metallo-supramolecular multicomponent assemblies, coexisting orthogonally in solution, serve as simplified mimics for complex networks found in biological systems. Building on recent advances in controlling the nonstatistical self-assembly of heteroleptic coordination cages and heteromeric completive self-sorting, i.e.

View Article and Find Full Text PDF

Acyl-anchored metal-organic cages with interior cryptand-like recognition sites for selective removal of radioactive strontium(II).

Sci Bull (Beijing)

December 2024

Laboratory of Nuclear Energy Chemistry, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China. Electronic address:

Tailored design of organic linkers or metal nodes can introduce desirable functionalities into metal-organic cages (MOCs), significantly expanding their potential applications. In this study, we present a viable approach for engineering acyl-type metal nodes to create interior oxygen-rich sites within MOCs, enabling specific recognition of metal ions, including radioactive contaminants, while maintaining the structural integrity of the MOCs. A novel MOC featuring a uranyl-sealed calix[4]resorcinarene (C[4]R)-based multisite cavity, referred to as UOC, is synthesized as a prototype.

View Article and Find Full Text PDF

The creation of hosts capable of accommodating different guest molecules may enable these hosts to play useful roles in chemical purifications, among other applications. Metal-organic cages are excellent hosts for various guests, but they generally incorporate rigid structural units that hinder dynamic adaptation to specific guests. Here we report a conformationally adaptable pseudo-cubic cage that can dynamically increase its cavity volume to fit guests with differing sizes.

View Article and Find Full Text PDF

Study Design: A meta-analysis approach to a systematic review.

Objective: Perform a systematic review to identify all reports directly comparing outcomes of lateral lumbar interbody fusion (LLIF) using static versus expandable interbody cages. Specifically focusing on periprocedural complications, intraoperative morbidity, and fusion outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!