The flow-through chambers described are easily assembled in the laboratory with no need for sophisticated or expensive equipment. They allow for treating micro-explants or single non-adhesive cells with different solutes for defined times by easy and quick changes of the medium in the chambers. The specimen can be fixed, immunostained and observed microscopically within the chamber. During these procedures the cells are not exposed to undue mechanical stress and fragile intercellular structures are well preserved.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1023/a:1024445010789 | DOI Listing |
Mikrochim Acta
December 2024
Frontier Research Centre, Songshan Lake Materials Laboratory, Dongguan, 523830, Guangdong, China.
Clinical and immunological assays of white blood cells (WBCs) in human peripheral blood are of significance for disease diagnosis and immunological studies. However, separating WBCs from blood with high recovery and high purity remains challenging. In this study, by incorporating a pair of linearly tapered filter arrays, a crossflow filtration-based microfluidic chip was designed and fabricated for separation of WBCs from blood.
View Article and Find Full Text PDFFront Microbiol
December 2024
Department of Molecular, Cellular, and Developmental Biology, University of California, Santa Barbara, Santa Barbara, CA, United States.
Symbiotic interactions drive species evolution, with nutritional symbioses playing vital roles across ecosystems. Chemosynthetic symbioses are globally distributed and ecologically significant, yet the lack of model systems has hindered research progress. The giant ciliate and its sulfur-oxidizing symbionts represent the only known chemosynthetic symbiosis with a short life span that has been transiently cultivated in the laboratory.
View Article and Find Full Text PDFACS ES T Water
December 2024
Berliner Wasserbetriebe, Neue Jüdenstraße 1, 10179 Berlin, Germany.
We present a versatile flow-through tube passive sampling device (TPS), with a controllable feedwater volumetric flow, that can be calibrated against the feedwater load of organic micropollutants (OMPs). This semipassive approach has the advantage of a determinable water load feeding the sampling device. The design of the TPS allows for new sampling scenarios in closed piping while providing stable and controlled sampling conditions.
View Article and Find Full Text PDFInt J Lab Hematol
December 2024
LabPLUS, Auckland City Hospital, Auckland, New Zealand.
Introduction: The TECHNOSCREEN ADAMTS-13 assay (ADSC) is a new lateral flow test which is simple and quick to perform, with a high negative predictive value (NPV); it may improve the diagnostic workflow for TTP. LabPlus in Auckland, New Zealand, performs all ADAMTS13 tests in the Auckland and Northland regions. The ADSC was used at LabPlus between 2022 and 2023 as part of a protocol where results of 0 IU/mL and 0.
View Article and Find Full Text PDFACS Biomater Sci Eng
January 2025
Department of Biomedical Engineering, University of Delaware, Newark, Delaware United States 19713.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!