A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Myocardial blood flow parameters derived from contrast replenishment using harmonic power Doppler imaging are underestimated by ultrasound signal attenuation. | LitMetric

The effect of ultrasound signal attenuation on myocardial blood flow parameters derived from contrast replenishment was evaluated using harmonic gray-scale (HGS) and harmonic power Doppler (HPD) imaging. In vitro experiments were performed in a flow model, whereas in vivo experiments were performed in 5 open-chest dogs. In each study, intermittent HGS and HPD images were acquired at various pulsing intervals during contrast infusion. A silicone pad was interposed between the transducer and target region to simulate attenuation conditions. Baseline-subtracted HGS and HPD signal intensities were measured with and without silicone pad, and myocardial blood flow parameters A and beta were calculated using contrast replenishment. Attenuation with HGS images could be offset by baseline subtraction, as baseline images provided the reference for attenuation. However, attenuation with HPD images could not be compensated for, as baseline signal intensity was theoretically 0. In HGS mode, silicone attenuation produced no significant decreases in A and beta. In HPD mode, however, A and beta were significantly decreased by silicone attenuation (A, P <.001; beta, P <.05). Compared with nonattenuated regions, myocardial blood flow parameters in attenuated regions are underestimated when HPD imaging is used. Baseline-subtracted HGS imaging may be useful to compensate for thoracic wall attenuation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0894-7317(03)00405-XDOI Listing

Publication Analysis

Top Keywords

myocardial blood
12
blood flow
12
flow parameters
12
contrast replenishment
12
parameters derived
8
derived contrast
8
harmonic power
8
power doppler
8
ultrasound signal
8
attenuation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!