Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The effect of ultrasound signal attenuation on myocardial blood flow parameters derived from contrast replenishment was evaluated using harmonic gray-scale (HGS) and harmonic power Doppler (HPD) imaging. In vitro experiments were performed in a flow model, whereas in vivo experiments were performed in 5 open-chest dogs. In each study, intermittent HGS and HPD images were acquired at various pulsing intervals during contrast infusion. A silicone pad was interposed between the transducer and target region to simulate attenuation conditions. Baseline-subtracted HGS and HPD signal intensities were measured with and without silicone pad, and myocardial blood flow parameters A and beta were calculated using contrast replenishment. Attenuation with HGS images could be offset by baseline subtraction, as baseline images provided the reference for attenuation. However, attenuation with HPD images could not be compensated for, as baseline signal intensity was theoretically 0. In HGS mode, silicone attenuation produced no significant decreases in A and beta. In HPD mode, however, A and beta were significantly decreased by silicone attenuation (A, P <.001; beta, P <.05). Compared with nonattenuated regions, myocardial blood flow parameters in attenuated regions are underestimated when HPD imaging is used. Baseline-subtracted HGS imaging may be useful to compensate for thoracic wall attenuation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0894-7317(03)00405-X | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!