Background: By changing the design of the St. Jude Medical Regent prosthesis in shifting both sewing cuff and retaining ring into a completely supra-annular position, the Regent valve has a greater geometric orifice for a given outer diameter. Accordingly, in vitro studies have shown increased effective orifice areas (EOAs) and lower transvalvular gradients. The aim of our study was to determine in vivo transvalvular gradients and EOAs in patients after aortic valve replacement (AVR).

Methods: We investigated 75 patients at 12 to 21 months follow-up after AVR using transthoracic echocardiography. We determined left ventricular systolic and diastolic function, EOA, and transvalvular peak gradient parameters at rest. Outcomes were assessed using the NYHA classification and functional status.

Results: No patient experienced cardiac failure. The majority reported good functional status and good quality of life. Five (6.7 %) late deaths were observed within the surveillance period. At follow-up, 92 % of the patients had improved by at least one NYHA class. Transvalvular peak gradients at rest for patients with Regent valves were 25.4 +/- 7.7 mmHg, 19.2 +/- 4.6 mmHg, 15.6 +/- 5.8 mmHg, 14.6 +/- 5.5 mmHg, and 8.5 +/- 2.5 mmHg; EOAs were 1.38 +/- 0.32 cm2, 1.62 +/- 0.49 cm2, 2.24 +/- 0.83 cm2, 2.63 +/- 0.70 cm2, and 3.28 +/- 0.34 cm2 for valve sizes 19 mm, 21 mm, 23 mm, 25 mm, and 27 mm, respectively.

Conclusions: The SJM Regent valve shows excellent in vivo hemodynamics as confirmed by echocardiography. Clinically, 92 % of the patients improved by at least one NYHA class.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2003-40317DOI Listing

Publication Analysis

Top Keywords

+/- mmhg
20
+/-
10
jude medical
8
medical regent
8
regent valve
8
transvalvular gradients
8
transvalvular peak
8
patients improved
8
improved nyha
8
nyha class
8

Similar Publications

Objectives: In this study, the capacity of End-tidal carbon dioxide (EtCO2) levels to predict the risk of major cardiovascular events (MACE) in patients diagnosed with acute coronary syndrome and the relationship between risk scoring systems (TIMI, GRACE, HEART) and EtCO2 values were examined.

Methods: EtCO2 values of the patients in the study were measured with a capnography device. Each patient's MACE status was recorded.

View Article and Find Full Text PDF

Rationale: In critically ill patients receiving invasive mechanical ventilation, switching from controlled to assisted ventilation is a crucial milestone towards ventilator liberation. The optimal timing for switching to assisted ventilation has not been studied.

Objectives: Our objective was to determine whether a strategy of early as compared to delayed switching affects the duration of invasive mechanical ventilation, ICU length of stay, and mortality.

View Article and Find Full Text PDF

Introduction And Hypothesis: Measuring changes in the vaginal pressure profile (VPP) with the Femfit® by JUNOFEM during various sports will help improve understanding of the magnitude of pressures generated during such activities and the pelvic floor's response to those pressures. This could aid in selecting safe exercises for women with pelvic floor dysfunction. The primary aim of this study was to measure intravaginal pressure changes using a novel pressure sensor array (Femfit®) during high-risk sports activities in elite female athletes with and without stress urinary incontinence (SUI).

View Article and Find Full Text PDF

Precis: Goniotomy is effective in managing intraocular pressure in childhood glaucoma secondary to uveitis with cumulative probability of success 0.94 after 1 year and 0.77 after 5 years.

View Article and Find Full Text PDF

Background: Gastric accommodation (GA) testing is gaining clinical recognition as novel and minimally invasive modalities emerge. We investigated the feasibility of hybrid nuclear imaging volumetry (SPECT/CT) and combined high-resolution manometry-nutrient drink test (HRM-NDT) to assess GA.

Methods: In this non-randomized pilot study, [Tc]NaTcO gastric SPECT/CT (250 mL protocol) and proximal gastric HRM-NDT (~60 mL/min protocol) were performed separately within 30 days using Ensure Gold test meal (1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!