Objective: To determine outcome of and complications associated with prophylactic percutaneous laser disk ablation in dogs with thoracolumbar disk disease.
Design: Retrospective study.
Animals: 277 dogs.
Procedure: Medical records of dogs with a history of thoracolumbar disk disease in which the 7 intervertebral disks from T10-11 through L3-4 were ablated with a holmium-yttrium-aluminum-garnet laser inserted through percutaneously placed needles were reviewed. Complications and episodes of a recurrence of neurologic signs (eg, paresis or paralysis) were recorded. Owners were contacted by telephone for follow-up information.
Results: Nine of 262 (3.4%) dogs for which follow-up information was available had a recurrence of paresis or paralysis. Follow-up time ranged from 1 to 85 months (mean, 15 months); signs recurred between 3 and 52 months (mean, 15.1 months) after laser disk ablation. Acute complications occurred in 5 dogs and included mild pneumothorax in 1 dog, an abscess at a needle insertion site in 1 dog, and proprioceptive deficits in 3 dogs, 1 of which required hemilaminectomy within 1 week because of progression and severity of neurologic signs. One dog developed diskospondylitis.
Conclusions And Clinical Relevance: Results suggest that prophylactic percutaneous laser disk ablation is associated with few complications and may reduce the risk of recurrence of signs of intervertebral disk disease in dogs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2460/javma.2003.222.1733 | DOI Listing |
Front Med (Lausanne)
December 2024
Department of Physical Medicine and Rehabilitation, Ankara Etlik City Hospital, Ankara, Türkiye.
Introduction: High-frequency laser therapy has been increasingly used in several musculoskeletal disorders, but there is still a lack of evidence for the usage of the device in neck pain. This study aimed to compare the effectiveness of physiotherapy, high-frequency laser, and exercise therapy methods in the treatment of pain in cervical disk herniation.
Methods: It was a multicenter, randomized, controlled clinical trial.
Clin Oral Investig
December 2024
Department of Stomatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1095 Jiefang Avenue, Wuhan, Hubei Province, 430030, China.
Objectives: Caries is a significant public health challenge. Herein, novel tooth-targeting antimicrobial peptides (HABPs@AMPs) were developed by combining the antimicrobial peptide DJK-5 with hydroxyapatite (HA) binding peptides, providing a potential new strategy for caries management.
Materials And Methods: The minimal inhibitory concentration (MIC) and minimal biofilm inhibitory concentration (MBIC) values of HABPs@AMPs were determined via micro-broth dilution and crystal violet staining.
IUCrJ
January 2025
Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany.
We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework.
View Article and Find Full Text PDFActa Microbiol Immunol Hung
December 2024
1Department of Clinical Microbiology and Microbial Pathogenesis, University Hospital of Heraklion, 71500 Crete, Greece.
Aerococcus urinae is an uncommon uropathogen that mainly affect the elderly with predisposing conditions. Aim of the present study was to investigate the clinical and microbiological characteristics of patients with urinary tract infections (UTIs) by A. urinae and determine the antimicrobial susceptibility patterns of the isolates, over the last 3 years at our institution.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China.
The abrasives of traditional grinding wheels are usually randomly arranged on the substrate, reducing the number of effective abrasive grains involved in the machining during the grinding process. However, there are some problems such as uneven distribution of chip storage space, high grinding temperature, and easy surface burn. In trying to address this issue, an ultrasonic vibration 3D printing method is introduced to fabricate the structured CBN (Cubic Boron Nitride) grinding wheel.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!