The present study compared the contribution of visual information of hand and target position to the online control of goal-directed arm movements. Their respective contributions were assessed by examining how human subjects reacted to a change of the position of either their seen hand or the visual target near the onset of the reaching movement. Subjects, seated head-fixed in a dark room, were instructed to look at and reach with a pointer towards visual targets located in the fronto-parallel plane at different distances to the right of the starting position. LEDs mounted on the tip of the pointer were used to provide true or erroneous visual feedback about hand position. In some trials, either the target or the pointer LED that signalled the actual hand position was shifted 4.5 cm to the left or to the right during the ocular saccade towards the target. Because of saccadic suppression, subjects did not perceive these displacements, which occurred near arm movement onset. The results showed that modifications of arm movement amplitude appeared, on average, 150 ms earlier and reached a greater extent (mean difference=2.7 cm) when there was a change of target position than when a change of the seen hand position occurred. These findings highlight the weight of target position information to the online control of arm movements. Visual information relative to hand position may be less contributive because proprioception also provides information about limb position.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00221-003-1504-7 | DOI Listing |
ACS Photonics
January 2025
Center for Nanophotonics, AMOLF, Science Park 104, XG Amsterdam 1098, the Netherlands.
We present a complete framework of stochastic thermodynamics for a single-mode linear optical cavity driven on resonance. We first show that the steady-state intracavity field follows the equilibrium Boltzmann distribution. The effective temperature is given by the noise variance, and the equilibration rate is the dissipation rate.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Program of Physical Therapy, Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.
Background: Ankle joint position sense (AJPS) accuracy and postural control are crucial for maintaining balance and stability, particularly in individuals with plantar fasciitis who may experience proprioceptive and functional impairments. Understanding how psychosocial factors, such as pain catastrophizing, and biomechanical measures, like muscle strength and gait parameters related to proprioception and postural control, can inform more effective treatment approaches. This study aimed to (1) examine the relationship between AJPS accuracy and biomechanical factors-including postural stability, lower limb muscle strength, and gait parameters-in individuals with plantar fasciitis d (2) analyze the impact of psychosocial factors, including pain catastrophizing, physical activity level, and quality of life, on AJPS accuracy and postural control in this population.
View Article and Find Full Text PDFGait Posture
January 2025
Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, Saint-Joseph University of Beirut, Beirut, Lebanon; Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers, Paris, France. Electronic address:
Background: Adult spinal deformity (ASD) is associated with muscles' degeneration that affects postural control and outcomes of an eventual corrective surgery. Evaluation of ASD is usually based on static radiographs and more recently on functional assessment. However, there has been limited exploration of muscle strength weakness in ASD.
View Article and Find Full Text PDFSci Data
January 2025
School of Informatics, The University of Edinburgh, Edinburgh, EH8 9AB, United Kingdom.
Myoelectric control has emerged as a promising approach for a wide range of applications, including controlling limb prosthetics, teleoperating robots and enabling immersive interactions in the Metaverse. However, the accuracy and robustness of myoelectric control systems are often affected by various factors, including muscle fatigue, perspiration, drifts in electrode positions and changes in arm position. The latter has received less attention despite its significant impact on signal quality and decoding accuracy.
View Article and Find Full Text PDFAntimicrob Steward Healthc Epidemiol
July 2024
Department of Public Health and Preventive Medicine, State University of New York Upstate Medical University, Syracuse, NY, USA.
Objective: The acceptability of an electronic HH monitoring system (EHHMS) was evaluated among hospital staff members.
Design: An electronic HH monitoring system was implemented in June 2020 at a large, academic medical center. An interdisciplinary team developed a cross-sectional survey to gather staff perceptions of the EHHMS.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!